background image

Applicable specification by each segment 

Standard specifications

Connection diagram and selection of wiring devices

Terminal functions

External dimensions

List of parameters 

For inverter users

Peripheral devices

Totally enclosed box type

3

5

7

8

9

10

13

16

21

Contents

Control terminal

 board

Communication

option board

Side-by-side installation

Conveyors

Stairway elevators

Commercial ironing boards

Treadmills

Control panels

Band tighteners

Printing presses

Fans in air-conditioning systems

Fans/blowers

Pumps

Buildings

Car washing machines

Food machines

Line-up

Example of generated noise data

110
100

90
80
70
60
50
40
30
20
10

0

0.15

1

10

30

dB

µ

V

﹈  

[MHz] 

Noise level when a noise
filter is not provided

Noise level of 
VFS11-4015PL

For users who need large starting torque

Conveyors, hoists, stairway elevators, and other conveyance 
machinery often need a large torque at startup. The VF-S11 
incorporates a TOSHIBA proprietary control system -- current 
vector calculation control -- to generate starting torque of 1Hz - 
200% or more*. This provides sufficient leeway in applications that 
require large starting torque. 

 

*When a TOSHIBA standard 4-pole motor 
is the drive source(Torque may differ 
according to voltage and model.)

For users with limited installation space

The VF-S11 has been downsized considerably in comparison 
with conventional models. In addition, side-by-side installation 
means that you can further save space as two or more units can 
be installed in close proximity next to each other.

For users who place importance on maintenance

Fans, pumps, blowers, and air-conditioning equipment must be 
maintained on a regular basis. The VF-S11 monitors the 
expected replacement period of spare parts and outputs an 
alarm to serve as a rough guideline for when to perform 
maintenance. Capacitors on the main circuit have been 
designed to have a life of 10 years*. In addition, the VF-S11 can 
be used in an ambient temperature of up to 60

°

C and 

demonstrates excellent environmental resistance. 

* Ambient temperature: annual average 40

°

C, output current: 80% of rated 

current, 24-hour operation 365 days per year

For users who need expandability

You often need to control and monitor systems by communications, 
for example, in building air-conditioning systems and plant line control 
systems. 
As well as being highly expandable, the VF-
S11 uses a detachable type of control 
terminal board, which allows you to easily 
mount optionally available communication 
boards (RS-485, DeviceNet* and 
LonWorks).  

* DeviceNet is a registered trademarks of ODVA(Open
DeviceNet Vendor Association)

 

For users who need a wide capacity and range of models

For obtaining spare parts and easy maintenance for the same 
machinery and facilities, wouldn't you like a lineup of the same 
kind of inverters? 
For an inverter in its class, the VF-S11 boasts a broad capacity 
range extending up to 15 kW. The VF-S11 also comes in a 
lineup of totally enclosed box types that can be used in severe 
installation environments subject to lots of water and dust.

For users troubled by electromagnetic noise

Equipment such as commercial ironing boards, car washers and 
indoor running machines, that are used in the fields of health, 
medicine and welfare care, the environment and in our daily lives, 
cause a great deal of trouble to 
the surrounding area if they 
generate electromagnetic noise. 
The VF-S11 incorporates a noise 
filter in its compact body to 
drastically reduce any generated 
electromagnetic noise. The VF-
S11 also complies with the EU 
EMC Directive. (See page 4.)

Detachable terminal board

They look the same, 

but if you crack the shell you can see the difference.

The VF-S11 reveals the potential and future of inverters.

ISO-9001 certification

This product is designed and
manufactured at plants that
have acquired ISO-9001
certification, the worldwide
quality assurance benchmark.

ISO-14001 certification

The plants that manufacture
this product are registered as
compliant with ISO-14001, the
environmental management
system.

Compatible with the World's Main Standards

 (EC Directive (CE marking), UL, CSA)

VF-S11   

- The easy-to-use inverter for a  variety of machines and facilities

New Global Standard Inverter

 

TOSVERT

TM

 

Applicable motor (kW)

0.2

0.4 0.55 0.75 1.5

2.2

4.0

5.5

7.5

11

15

*

 1: 0.55kW model is 3-phase 240V class IP20 type only.

*

 2: IP54 type is possible to bring into compliance with IP55 specification.

*1

3-phase 600V

1-phase 240V

3-phase 240V

3-phase 500V

Input Voltage 

Class

IP20

IP54

IP20

IP20

IP20

IP00

*2

IP54

*2

IP54

*2

Example of torque data

500

-100

-200

0

100

200

1000

1500

2000

2500

T

orque

 [%]

Speed [min-1]

* When a TOSHIBA standard 3-phase 220V - 2.2 kW 
  motor is driven by the VFS11-2022PM after 
  parameters are set

Содержание TOSVERT VF-S11

Страница 1: ...ns must be studied carefully When using our inverters for critical equipment even though the inverters are manufactured under strict quality control always fit your equipment with safety devices to prevent serious accident or loss should the inverter fail such as issuing an inverter failure signal Do not use our inverters for any load other than three phase induction motors None of Toshiba its sub...

Страница 2: ...ditioning systems and plant line control systems As well as being highly expandable the VF S11 uses a detachable type of control terminal board which allows you to easily mount optionally available communication boards RS 485 DeviceNet and LonWorks DeviceNet is a registered trademarks of ODVA Open DeviceNet Vendor Association For users who need a wide capacity and range of models For obtaining spa...

Страница 3: ...omentary monitor values for when a trip occurs can be viewed Ten monitor values are stored in memory for the last four inverter operations which is effective in pin pointing the cause of a trip Storage of user parameter settings All parameter settings made by the user can be stored in memory Stored parameters can be immediately called even they have been changed History function This function is f...

Страница 4: ...the range of 50 to 600V by correcting the supply voltage not adjustable above the input voltage 0 5 to 500 0Hz default setting 0 5 to 80Hz maximum frequency 30 to 500Hz 0 01Hz operation panel setting 0 1Hz analog input when the max frequency is 100Hz V f constant variable torque automatic torque boost vector control automatic energy saving dynamic automatic energy saving control Auto tuning Base f...

Страница 5: ...g across F CC causes forward rotation open causes slowdown and stop Shorting across R CC causes reverce rotation open causes slowdown and stop RES S1 S2 S3 Shorting across S1 CC causes preset speed operation Shorting across S2 CC causes preset speed operation Shorting across S3 CC causes preset speed operation CC PLC Control circuit s equipotential terminal sink logic 3 common terminals for input ...

Страница 6: ... 5 5 0 5 1 9 6 9 6 1 0 1 0 1 2 1 4 2 2 1 3 1 3 2 1 2 2 4 7 4 7 8 8 8 8 3 phase 240V 3 phase 500V Input voltage Applicable motor kW Type H W D H1 H2 Approx weight kg W1 D2 Drawing Dimensions mm 0 4 0 55 0 75 1 5 2 2 4 0 5 5 7 5 11 15 0 4 0 75 1 5 2 2 4 0 5 5 7 5 11 15 0 2 0 4 0 75 1 5 2 2 0 75 1 5 2 2 4 0 5 5 7 5 11 15 VFS11 2004PM VFS11 2005PM VFS11 2007PM VFS11 2015PM VFS11 2022PM VFS11 2037PM VF...

Страница 7: ...rs Protection parameters Set to generate high torque to match load or motor Torque up parameters Set if changing units displayed or various display methods Panel display parameters List of parameters 12 DC Braking parameters Title Function Adjustment range Default setting DC braking starting frequency DC braking current DC braking time Motor shaft fixing control 0 0 Hz 0 100 A 0 0 20 0 s 0 Invalid...

Страница 8: ...put and output cables etc of the inverter To prevent current leakage it is recommended to take the following measures Effects of leakage current Leakage current which increases when an inverter is used may pass through the following routes Route 1 Leakage due to the capacitance between the ground and the noise filter Route 2 Leakage due to the capacitance between the ground and the inverter Route ...

Страница 9: ...CL High attenuation radio noise filter NF type Braking resistor Conduit pipe attachment kit Motor end surge voltage suppression filter for 500V class only Zero phase reactor ferrite core type EMC noise filter Compliant with European standards P 17 P 18 P 18 P 9 P 20 P 20 P 19 P 18 P 19 P 19 P 19 P 20 Used to improve the input power factor reduce the harmonics and suppress external surge on the inv...

Страница 10: ...ox with cover 4 ØF holes AC reactor Power source AC reactor Power source P Earth terminal Power source LC filter Model Rated current A Inverter type Diagram Terminals Approx weight kg Dimensions mm W H D X Y d1 d2 DCLS 2002 DCL 2007 DCL 2022 DCL 2037 DCL 2055 DCL 2110 DCL 2220 DCL 2007 DCL 2022 DCL 4110 DCL 4220 2 5 7 14 22 5 38 75 150 7 14 38 75 79 92 86 86 75 100 117 92 86 95 105 50 65 110 110 1...

Страница 11: ...devices 19 Devices External dimensions and connections Motor end surge voltage suppression filter for 500V class only Parameter writer Extension panel Motor end surge voltage suppression filter l Invertor type Approx weight kg MSF 4015Z MSF 4037Z MSF 4075Z MSF 4150Z Dimensions mm Depth 12 20 30 40 Terminal screw M4 M4 M5 M5 Grounding screw M4 M4 M5 M5 VFS11 4004 4015PL VFS11 4022 4037PL VFS11 4055...

Страница 12: ...it breaker Minimum wiring Cooling structure Self cooling type 22 21 Command mode selection Frequency setting mode selection 1 0 Function VF S11 Standard type 0 2 VF S11 otally enclosed type Title External dimensions Fig F 3ph 240V 3ph 500V 1ph 240V VFS11 2004PME VFS11 2007PME VFS11 2015PME VFS11 2022PME VFS11 2037PME VFS11 4007PLE VFS11 4015PLE VFS11 4022PLE VFS11 4037PLE VFS11 4055PLU VFS11 4075P...

Отзывы: