24
GROUP:PATTERN RUN CONTROL PARAMETERS (Cont.)
Reg.
Function / Title
Bank
Address
Mask
Adjustment Range
Multiplier
173
Less than 4
SPEED #1 DRIVE TIME
1
052C
FFFF
0000
∼
1F40 (0
∼
8000)
1
174
SPEED #2 CONTINUE MODE
1
0536
00FF
Same as SPEED #1
CONTINUE MODE
175
Less than 4
SPEED #2 DRIVE TIME
1
0534
FFFF
0000
∼
1F40 (0
∼
8000)
1
176
SPEED #3 CONTINUE MODE
1
053E
00FF
Same as SPEED #1
CONTINUE MODE
177
Less than 4
SPEED #3 DRIVE TIME
1
053C
FFFF
0000
∼
1F40 (0
∼
8000)
1
178
SPEED #4 CONTINUE MODE
1
0546
00FF
Same as SPEED #1
CONTINUE MODE
179
Less than 4
SPEED #4 DRIVE TIME
1
0544
FFFF
0000
∼
1F40 (0
∼
8000)
1
17A
SPEED #5 CONTINUE MODE
1
054E
00FF
Same as SPEED #1
CONTINUE MODE
17B
Less than 4
SPEED #5 DRIVE TIME
1
054C
FFFF
0000
∼
1F40 (0
∼
8000)
1
17C
SPEED #6 CONTINUE MODE
1
0556
00FF
Same as SPEED #1
CONTINUE MODE
17D
Less than 4
SPEED #6 DRIVE TIME
1
0554
FFFF
0000
∼
1F40 (0
∼
8000)
1
17E
SPEED #7 CONTINUE MODE
1
055E
00FF
Same as SPEED #1
CONTINUE MODE
17F
Less than 4
SPEED #7 DRIVE TIME
1
055C
FFFF
0000
∼
1F40 (0
∼
8000)
1
180
SPEED #8 CONTINUE MODE
1
0566
00FF
Same as SPEED #1
CONTINUE MODE
181
Less than 4
SPEED #8 DRIVE TIME
1
0564
FFFF
0000
∼
1F40 (0
∼
8000)
1
182
SPEED #9 CONTINUE MODE
1
056E
00FF
Same as SPEED #1
CONTINUE MODE
183
Less than 4
SPEED #9 DRIVE TIME
1
056C
FFFF
0000
∼
1F40 (0
∼
8000)
1
184
SPEED #10 CONTINUE MODE
1
0576
00FF
Same as SPEED #1
CONTINUE MODE
185
Less than 4
SPEED #10 DRIVE TIME
1
0574
FFFF
0000
∼
1F40 (0
∼
8000)
1
186
SPEED #11 CONTINUE MODE
1
057E
00FF
Same as SPEED #1
CONTINUE MODE
187
Less than 4
SPEED #11 DRIVE TIME
1
057C
FFFF
0000
∼
1F40 (0
∼
8000)
1
188
SPEED #12 CONTINUE MODE
1
0586
00FF
Same as SPEED #1
CONTINUE MODE
189
Less than 4
SPEED #12 DRIVE TIME
1
0584
FFFF
0000
∼
1F40 (0
∼
8000)
1
18A
SPEED #13 CONTINUE MODE
1
058E
00FF
Same as SPEED #1
CONTINUE MODE
18B
Less than 4
SPEED #13 DRIVE TIME
1
058C
FFFF
0000
∼
1F40 (0
∼
8000)
1
18C
SPEED #14 CONTINUE MODE
1
0596
00FF
Same as SPEED #1
CONTINUE MODE
18D
Less than 4
SPEED #14 DRIVE TIME
1
0594
FFFF
0000
∼
1F40 (0
∼
8000)
1
18E
SPEED #15 CONTINUE MODE
1
059E
00FF
Same as SPEED #1
CONTINUE MODE
18F
Less than 4
SPEED #15 DRIVE TIME
1
059C
FFFF
0000
∼
1F40 (0
∼
8000)
1
8.3.9
GROUP:FEEDBACK CONTROL PARAMETERS
Reg.
Function / Title
Bank
Address
Mask
Adjustment Range
Multiplier
190
FEEDBACK CONTROL SELECTION
0 / 1
04B9
0060
0000: No feedback
0001: PID control
0002: Speed feedback
191
1
•
2
FEEDBACK INPUT SIGNAL SELECTION
0 / 1
04B9
001C
0001: RR input
0002: IV input
0003: RX input
0004: PG feedback
0005: RS232C input
0006: Communication/12-bit
binary option board
0007: BIN input
192
PROPORTIONAL GAIN
0 / 1
04A8
00FF
0001
∼
00FF (0.01
∼
2.55)
0.01
193
INTEGRAL GAIN
0 / 1
04AA
FFFF
0001
∼
8CA0 (0.01
∼
360.00)
0.01
194
ANTI-HUNTING GAIN
0 / 1
04AC
00FF
0000
∼
00FF (0.0
∼
25.5)
0.1
195
LAG TIME CONSTANT
0 / 1
04AD
00FF
0000
∼
00FF (0
∼
255)
1
196
PID LOWER LIMIT FREQUENCY
0 / 1
03D2
FFFF
0
∼
Fmax
0.01