22
8.3.7
GROUP:PROTECTION FUNCTION PARAMETERS
Reg.
Function / Title
Bank
Address
Mask
Adjustment Range
Multiplier
11F
DYNAMIC BRAKING SELECTION
(Note)
0 / 1
04BD
0003
0000: no dynam. Braking
0001: with dynamic braking,
no DBR OL trip
0002: with dynamic braking
and DBR OL trip
120
2
BRAKING RESISTOR VALUE
0 / 1
0416
FFFF
000A
∼
2710 (1.0
∼
1000)
0.1
121
BRAKING RESISTOR POWER RATING
0 / 1
0418
FFFF
0001
∼
EA60 (0.01
∼
600.00)
0.01
122
OVERVOLTAGE STALL PROTECTION
0 / 1
04BD
0004
0000: ON
0001: OFF
123
DC INJECTION START FREQUENCY
0 / 1
03FC
FFFF
0000
∼
2EE0 (0.00
∼
120.00)
0.01
124
Other
DC INJECTION CURRENT MAGNITUDE
0 / 1
043A
00FF
0000
∼
0064 (0
∼
100)
1
125
than 0
DC INJECTION TIME
0 / 1
043B
00FF
0000
∼
0064 (0.0
∼
10.0)
0.1
126
FWD/REV DC INJECTION PRIORITY CTRL
0 / 1
04BC
0040
0000: OFF
0001: ON
127
MOTOR SHAFT STATIONARY CTRL
0 / 1
04BC
0080
0000: OFF
0001: ON
128
EMERGENCY OFF MODE SELECTION
0 / 1
04BC
0030
0000: Coast stop
0001: Decelerated stop
0002: DC injection stop
129
2
EMERGENCY OFF DC INJECTION TIME
0 / 1
043D
00FF
0000
∼
0064 (0.0
∼
10.0)
0.1
12A
NUMBER OF RETRY ATTEMPTS
0 / 1
043F
00FF
0000
∼
000A (0
∼
10)
1
12B
Other
than 0
TIME BETWEEN RETRY ATTEMPTS
0 / 1
0440
00FF
0000
∼
0064 (0.0
∼
10.0)
0.1
12C
REGENERATION POWER RIDE-THROUGH
0 / 1
04BD
0008
0000: OFF
0001: ON
12D
1
REGENERATION RIDE-THROUGH TIME
0 / 1
0446
00FF
0000
∼
00FA (0.0
∼
25.0)
0.1
12E
AUTO-RESTART (MOTOR SPEED SEARCH)
0 / 1
04B6
0018
0000: OFF
0001: On power failure
0002: On ST make/break
0003: Both (1) and (2)
12F
ELECTRONIC THERMAL PROTECT LVL #1
0 / 1
042A
00FF
000A
∼
0064 (10
∼
100)
1
130
OVERLOAD REDUCTION START FREQ
0 / 1
0410
FFFF
0000
∼
0BB8 (0.00
∼
30.00)
0.01
131
MOTOR 150% OVERLOAD TIME LIMIT
0 / 1
0444
00FF
0001
∼
00F0 (10
∼
2400)
10
132
OVERLOAD SELECTION
0 / 1
04BD
0030
0000: with motor overload trip,
w/o soft-stall
0001: with motor overload trip
and soft-stall
0002: w/o soft-stall or motor
overload trip
0003: with soft-stall, w/o motor
overload trip
133
STALL PROTECTION ENABLE
0 / 1
042D
0040
0000: ON
0001: OFF
134
0
STALL PROTECTION CURRENT LEVEL
0 / 1
042B
00FF
000A
∼
00D7 (10
∼
215)
1
135
UNDERVOLTAGE TRIP SELECTION
0 / 1
04BD
0080
0000: Trip disabled
0001: Trip (during run)
136
UNDERVOLTAGE DETECT TIME
0 / 1
0414
FFFF
0000
∼
03E8 (0.00
∼
10.00)
0.01
137
LOW CURRENT DETECT SELECTION
0 / 1
04BC
0008
0000: Trip disabled
0001: Trip on detection
138
LOW CURRENT DETECT LEVEL
0 / 1
0441
00FF
0000
∼
0064 (0
∼
100)
1
139
LOW CURRENT DETECTION TIME
0 / 1
0442
00FF
0000
∼
00FF (0
∼
255)
1
140
OUTPUT SHORT-CIRCUIT DETECTION SELECT
0 / 1
04BE
0003
0000: Standard motor
0001: High-speed motor
0002: Positioning use
(standard motor)
0003: Positioning use (high-
speed motor)
141
OVERTORQUE TRIP SELECTION
0 / 1
04BE
0040
0000: Trip disabled (0)
0001: Trip enabled (1)
142
OVERTORQUE TRIP LEVEL
0 / 1
0443
00FF
0000
∼
00C8 (0
∼
200)
1