TMP92CZ26A
92CZ26A-329
7 6 5 4 3 2 1 0
bit
Symbol RB8 EVEN PE OERR
PERR
FERR
SCLKS
IOC
Read/Write
R
R/W
R (cleared to 0 when read)
R/W
After
Reset
Undefined
0 0 0 0 0 0 0
Function
Received
data bit 8
Parity
0: odd
1: even
Parity
addition
0: disable
1: enable
Overrun
Parity Framing
0: SCLK0
1: SCLK0
0: baud rate
generator
1: SCLK0
pin input
SC0CR
(1201H)
I/O interface input clock selection
Framing Error flag
Parity Error flag
Overrun Error flag
0
Transmits and receivers
data on rising edge of SCLK0.
1
Transmits and receivers
data on falling edge SCLK0.
Edge selection for SCLK pin (Input / Output Mode)
0
Disabled
1
Enabled
Parity addition enables
Even parity addition/check
1: error
0
Baud rate generator
1
SCLK0 pin input
Cleared to 0
when read
0
Odd parity
1
Even parity
Received data 8
Prohibit
to Read
modify
Write
Note: As all error flags are cleared after reading, do not test only a single bit with a bit-testing
instruction.
Figure 3.14.7 Serial Control Register (channel 0, SC0CR)