TMP92CZ26A
92CZ26A-317
3.14.2 Operation of Each Circuit
(1) Prescaler
There is a 6-bit prescaler for generating a clock to SIO0. The prescaler can be run by
selecting the baud rate generator as the serial transfer clock.
Table 3.14.1 shows prescaler clock resolution into the baud rate generator.
Table 3.14.1 Prescaler Clock Resolution to Baud Rate Generator
Clock Resolution
-
Clock gear
SYSCR1
<GEAR2:0>
-
φ
T0
φ
T2
φ
T8
φ
T32
000(1/1) f
SYS
/4 f
SYS
/16 f
SYS
/64 f
SYS
/256
001(1/2) f
SYS
/8
f
SYS
/32 f
SYS
/128 f
SYS
/512
010(1/4) f
SYS
/16
f
SYS
/64 f
SYS
/256 f
SYS
/1024
011(1/8) f
SYS
/32
f
SYS
/128
f
SYS
/512
f
SYS
/2048
fc
100(1/16)
1/4
f
SYS
/64 f
SYS
/256
f
SYS
/1024
f
SYS
/4096
XXX:Don’t care
The baud rate generator selects between 4-clock inputs:
φ
T0,
φ
T2,
φ
T8, and
φ
T32