![Toshiba TLCS-900 Family Скачать руководство пользователя страница 212](http://html.mh-extra.com/html/toshiba/tlcs-900-family/tlcs-900-family_data-book_425998212.webp)
TMP92CZ26A
92CZ26A-209
3.9.2.1
Program bank register
The bank number used as program memory is set to these registers. In certain bank, cannot
diverge directly to different bank of same local area. To change program bank number in the
same local area is disable.
LOCAL-X register for Program
7
6
5
4
3
2
1
0
bit Symbol
X7
X6
X5
X4
X3
X2
X1
X0
Read/Write R/W
After reset
0
0
0
0
0
0
0
0
Function
Set BANK number for LOCAL-X
(“0” is disabled because of overlapped with Common-area.)
15
14
13
12
11
10
9
8
bit Symbol
LXE
X8
Read/Write R/W
R/W
After reset
0
0
Function
BANK for
LOCALX
0: Disable
1: Enable
Set BANK number for LOCAL-X
X8-X0 setting and CS
000000000 to 011111111 CSXA
100000000 to 111111111 CSXB
LOCAL-Y register for Program
7
6
5
4
3
2
1
0
bit Symbol
Y5
Y4
Y3
Y2
Y1
Y0
Read/Write
R/W
After reset
0
0
0
0
0
0
Function
Set BANK number for LOCAL-Y
(“3” is disabled because of overlapped with Common-area.)
15
14
13
12
11
10
9
8
bit
Symbol
LYE
Read/Write R/W
After reset
0
Function
BANK for
LOCALY
0: Disable
1: Enable
LOCAL-Z register for Program
7
6
5
4
3
2
1
0
bit Symbol
Z7
Z6
Z5
Z4
Z3
Z2
Z1
Z0
Read/Write R/W
After
reset
0 0 0 0 0 0 0 0
Function
Set BANK number for LOCAL-Z
(“3” is disabled because of overlapped with Common-area.)
15
14
13
12
11
10
9
8
bit Symbol
LZE
Z8
Read/Write R/W
R/W
After reset
0
0
Function
BANK for
LOCALZ
0: Disable
1: Enable
Set BANK number for LOCAL-Z
Z8-Z0 setting and CS
000000000 to 001111111 CSZA
100000000 to 101111111 CSZC
010000000 to 011111111 CSZB
110000000 to 111111111 CSZD
LOCALPX
(880H)
(881H)
LOCALPY
(882H)
(883H)
LOCALPZ
(884H)
(885H)