TC32306FTG
2015-10-01
34
Table 6-37 Single Read/Write and Burst Read/Write
Function
Explanation
Single Read/Write
To read and write only specified address register data. It is available for accessing to
single or non-continuous address registers.
Burst Read/Write
To read and write in order from the specified address register data.
It is available for accessing to continuous address registers. To specify the start
address only causes to shorten the read/write time.
6.7.3 SPI Control Data Format
SPI control data format of TC32306FTG is constructed by instruction (8 bit), address (8 bit) and data
(8 bit).
Fig 6-14 SPI Control Data Format
In SPI Mode, Single / Burst, Write / Read and Confirmation of written data are set by instruction data.
Enter each SPI control data sequentially from most significant bit (MSB).
Table 6-38 Type of SPI Instructions and Settings
SPI Control
I7
I6
I5
I4
I3
I2
I1
I0
Single Read/Write
Write
0
0
0
0
X
1
1
0
Read
0
0
0
0
X
1
1
1
Burst Read/Write
Write
0
0
0
0
X
0
1
0
Read
0
0
0
0
X
0
1
1
Confirmation of written data
0
0
0
0
X
1
0
1
Stop SPI Function
Except above data
* x: 0 or 1
* Stop SPI Function: After entering SPI instruction data, subsequent data input will be invalid. To enable the
input data again, enter SPI instruction data correctly after CS pin is set to be "H" once.
D0
D1
D2
D3
D4
D5
D6
D7
AD0
AD1
AD2
AD3
AD4
AD5
AD6
AD7
Instruction
(8bit)
Address
(8bit)
Read Data
(8bit)
I7
I6
I5
I4
I3
I2
I2
I0
MSB
MSB
MSB
LSB
LSB
LSB