System Capacities
Announcing Strata CIX1200 Expanded Capacity
31 of 37
Table 14
Station/Peripherals System Capacities
Stations
CIX1200
EXP. B
HCTU+HEXBU
CIX1200
EXP. A
HCTU+HEXA
CIX1200
BASIC
HCTU
CIX670
Expanded
Processor
BCTU + BEXU
CIX670
Basic
Processor
BCTU
DKT2000, 3000, 3200,
5000 series
1
1 Limited by power factor
952
552
152
552
152
DKT2000, 3000, 3200,
5000 series per cabinet
72 (Base)
80 (Exp)
72 (Base)
80 (Exp)
72 (Base)
80 (Exp)
72 (Base)
80 (Exp)
72 (Base)
80 (Exp)
IPT telephones
2
2 Limited by system traffic
80 (Base)
80 (Exp)
1000 System
80 (Base)
80 (Exp)
560 System
80 (Base)
80 (Exp)
160 System
80 (Base)
80 (Exp)
560 System
80 (Base)
80 (Exp)
160 System
DAMA per Base
cabinet
1
55 DPs with
1 ADM
43 DPs with 2
ADMs
55 DPs with
1 ADM
43 DPs with 2
ADMs
57 DPs with
1 ADM
43 DPs with 2
ADMs
55 DPs with
1 DADM
43 DPs with
2 DADMs
55 DPs with
1 DADM
43 DPs with
2 DADMs
DADM per Expansion
cabinet
1
‘
57 DPs with
1 ADM
45 DPs with 2
ADMs
57 DPs with
1 ADM
45 DPs with 2
ADMs
55 DPs with
1 ADM
45 DPs with 2
ADMs
57 DPs with
1 DADM
45 DPs with
2 DADMs
57 DPs with
1 DADM
45 DPs with
2 DADMs
IADM on IPT
3
3 Limited by the number of flexible buttons per system
84/cabinet
80/cabinet
80/cabinet
80/cabinet
80/cabinet
IADM System Capacity
800/system
400/system
116/system
400/system
116/system
DKT2204-CT or
2304-CT
952
552
152
552
152
CIX Attendant Console
6
6
6
4
2
Door locks
4
4 Each Door lock reduces the number of Door Phones by one Door Phone and vice versa.
10
10
5
10
5
Door phone control boxes
(DDCB)
8
8
3
8
3
Door phones
24
24
9
24
9
DSS consoles (DSS)
24 per System
8 per Station
24 per System
8 per Station
5 per System
5 per Station
15 per System
8 per Station
5 per System
5 per Station
Off-premise stations
944
544
144
544
144
BPCI used for TAPI
only per cabinet
66
66
66
66
66
Total Stations (Digital/
Analog/IP combined)
1000
560
160
560
160
Standard Station
944
544
144
544
144
DTMF Receivers
48
32
16
32
16
Calls existing at the
same time
576
336
96
336
96