DK424 Configuration
Printed Circuit Boards
4-16
Strata DK I&M 6/00
RKYS Feature Key Upgrades
The system can be upgraded for built-in AA, Automatic Call Distribution (ACD), Software
Management Information System (SMIS) for ACD with feature keys that attach to the common
control unit. See
for a list of features provided by RKYS feature keys.
Table 4-18
RKYS Features
Option Interface PCBs for the DK424 are listed in
. Refer to Chapter 12 – Peripherals
for further information on these options.
1. PIOU, PIOUS, and RSSU each provide one TTY port which can be flexibly programmed for the features marked with X.
RSIU/RSIS can provide up to four flexible TTY/SMDR ports.
2. Maintenance modem, ACD/SMIS, Insight DK, Voice Mail, SMDI and DKi Admin PC Interface each require a separate TTY
output. PIOU, PIOUS, and RSSU provide one TTY output each. RSIU with RSIS PCBs provides up to four TTY outputs.
3. SMDR output will function simultaneously on the same PIOU or PIOUS with one of the following: DKi Admin, remote
modem, SMIS for ACD, Insight DK, or SMDI features.
4. Insight DK, Call Center Viewer and SMIS for ACD requires that the system processor (RCTU PCB) must be equipped with an
RKYS3 or higher feature key.
Feature(s) Provided
RKYS1
RKYS2
RKYS3
Common Control Unit
Built-in Auto Attendant
X
X
X
Applies to all RCTUs
ACD
X
X
RCTUBA/BB, RCTUC/D or RCTUE/F
ACD with a SMIS application
X
RCTUBA/BB, RCTUC/D or RCTUE/F
Table 4-19
DK424 Interface PCB Options
Interface Options
RSSU
1
PIOU
1
PIOUS
1
PEPU
RSIU/
RSIS
1
Zone page interface (unamplified, 4 zones)
X
Unamplified page output (single zone, 600 ohms, duplex)
X
X
X
Amplified page output (single zone, 3 watts, 8 ohms)
X
X
Night transfer or Music-on-hold control relay
X
X
X
Door lock or external amplifier control relay
X
X
X
Alarm Sensor
X
X
Remote maintenance modem subassembly (IMDU or RMDS)
(disables TTY output when they are piggy-backed onto the PIOU/
PIOUS or RSIU/RSIS cards)
2
X
(IMDU)
X
(IMDU)
X
(IMDU)
Remote Maintenance using customer-provided external modem
(requires TTY output port)
X
X
X
X
SMDR output (RS-232/6-wire modular connector)
X
3
X
3
X
MIS for ACD (requires TTY output port)
2, 4
X
X
X
X
Voice Mail SMDI (requires TTY output port)
2
X
X
X
X
StrataControl and/or DKi Admin PC (requires TTY output port)
X
X
X
X
Содержание Strata AirLink DK40i
Страница 22: ...Introduction Related Documents Media xx Strata DK I M 6 00 ...
Страница 48: ...DK14 Installation DK14 Wiring Diagrams 1 26 Strata DK I M 6 00 ...
Страница 220: ...DK424 Installation Remote Cabinet Installation Instructions 5 68 Strata DK I M 6 00 ...
Страница 262: ...DK424i Configuration Primary Reserve Power Cabinet Hardware 6 42 Strata DK I M 6 00 ...
Страница 450: ...Universal Slot PCB Wiring Option Interface PCB Wiring Diagrams 10 42 Strata DK I M 6 00 ...
Страница 592: ...Peripheral Installation Enhanced 911 Service E911 12 84 Strata DK I M 6 00 ...
Страница 616: ...ACD Installation Spectrum Electronic Wall Boards 13 24 Strata DK I M 6 00 ...
Страница 634: ...Fault Finding Fault Isolation Flowcharts 14 18 Strata DK I M 6 00 ...
Страница 704: ...ISDN Interfaces ISDN Disconnect Cause Code 16 54 Strata DK I M 6 00 ...