– 11 –
Standard pressure
Surface temp. of heat
P
exchanger interchanging
Fan speed
50Hz
(MPaG)
pipe T1 (°C)
(indoor)
RAS-10SKH-ES
RAS-10SKH-ES
Standard
2,5
40,0
High
Heating
High temperature*1
3,1 ~ 3,6
51,0 ~ 58
Low
Low temperature
2,2
36,0
High
Standard
0,9
10,0
High
Cooling
High temperature
1,1
16,0
High
Low temperature
0,6
2,0
Low
5. REFRIGERANT CYCLE DIAGRAM
RAS-10SKH-ES/RAS-10SAH-ES
Note :
• Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor.)
*
1
• During heating overload, the high temperature limit control operation is included.
Evaporator
Indoor unit
Cross flow fan
Cooling
Heating
4-way valve
Heating Cooling
Compressor
Accumulator
Condenser
Propeller fan
Outdoor unit
Dryer
Capillary tube
ø0,8x400
PA118X1T-4FZ
Cooling
Heating
Mark( )means check points of Gas Leak
O.D.:9,52mm
O.D.:6,35mm
Cooling
Heating
Packed valve
(ø9,52)
Packed valve
(ø6,35)
0,39m
(Connecting pipe)
ø9,52
0,49m
(Connecting pipe)
ø6,35
T1
P
Refrigerant
R-410A 0,69kg
Capillary tube
ø1,2x400
Muffler
Muffler
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
20/–
7/6
27/–
21/15
20/–
–10/–10
27/19
35/24
32/23
43/26
21/15
21/15