Replacement Procedures
Satellite U840
Maintenance Manual (960-Q08)
4-4
Disassembly Procedure
Three main types of cable connector are used.
•
Pressure plate connector
•
Spring connector
•
Normal pin connector
When disconnecting a pressure plate connector, lift up the tag on one side of the plastic
pressure plate on the connector and pull the cable out from the connector. When reconnecting
a cable to a pressure plate connector, lift up the pressure plate to a suitable height and insert
the cable into the connector. Press down on both sides of the pressure plate such that both
sides of the plate and connector are at the same height and that the cable is fixed in the
correct position. Pull the cable to ensure that it is securely connected. If the cable is
disconnected from the connector, reconnect it making sure that you lift the pressure plate
high enough to insert fully the cable.
For spring connectors, lifting up the stopper frees the cable and allows it to be pulled out. To
reconnect, hold the stopper in the up position and insert the cable, then lower the stopper to
secure the cable.
Normal pin connectors are used for all other cables. Simply pull out or push in these
connectors to disconnect or reconnect.
Pressure plate connector
Spring connector
Содержание Satellite U840 Series
Страница 1: ...Satellite U840 Maintenance Manual 960 Q08 Chapter 1 Hardware Overview ...
Страница 18: ...Chapter 1 Hardware Overview Satellite U840 Maintenance Manual 960 Q08 15 ...
Страница 24: ...2 1 Satellite U840 Maintenance Manual 960 Q08 Chapter 2 Troubleshooting Procedures ...
Страница 63: ...Test Program for Field Satellite U840 Tests and Diagnostics Manual 1 Chapter 3 Diagnostic Programs ...
Страница 190: ...Satellite U840 Maintenance Manual 960 Q08 Appendix B Appendix B Board Layout B 1 System Board ...
Страница 191: ...Board Layout Satellite U840 Maintenance Manual 960 Q08 Figure B 1 System board layout Front 02 01 03 04 05 06 07 08 09 ...