1-3-1
DVD_SFNP
IMPORTANT SAFETY PRECAUTIONS
Product Safety Notice
Some electrical and mechanical parts have special
safety-related characteristics which are often not evi-
dent from visual inspection, nor can the protection
they give necessarily be obtained by replacing them
with components rated for higher voltage, wattage,
etc. Parts that have special safety characteristics are
identified by a
!
on schematics and in parts lists. Use
of a substitute replacement that does not have the
same safety characteristics as the recommended
replacement part might create shock, fire, and/or other
hazards. The Product’s Safety is under review continu-
ously and new instructions are issued whenever
appropriate. Prior to shipment from the factory, our
products are carefully inspected to confirm with the
recognized product safety and electrical codes of the
countries in which they are to be sold. However, in
order to maintain such compliance, it is equally impor-
tant to implement the following precautions when a set
is being serviced
.
Precautions during Servicing
A.
Parts identified by the
!
symbol are critical for
safety. Replace only with part number specified.
B.
In addition to safety, other parts and assemblies
are specified for conformance with regulations
applying to spurious radiation. These must also be
replaced only with specified replacements.
Examples: RF converters, RF cables, noise block-
ing capacitors, and noise blocking filters, etc.
C.
Use specified internal wiring. Note especially:
1)Wires covered with PVC tubing
2)Double insulated wires
3)High voltage leads
D.
Use specified insulating materials for hazardous
live parts. Note especially:
1)Insulation tape
2)PVC tubing
3)Spacers
4)Insulators for transistors
E.
When replacing AC primary side components
(transformers, power cord, etc.), wrap ends of
wires securely about the terminals before solder-
ing.
F.
Observe that the wires do not contact heat produc-
ing parts (heatsinks, oxide metal film resistors, fus-
ible resistors, etc.).
G.
Check that replaced wires do not contact sharp
edges or pointed parts.
H.
When a power cord has been replaced, check that
5 - 6 kg of force in any direction will not loosen it.
I.
Also check areas surrounding repaired locations.
J.
Be careful that foreign objects (screws, solder
droplets, etc.) do not remain inside the set.
K.
When connecting or disconnecting the internal
connectors, first, disconnect the AC plug from the
AC outlet.
Содержание RD-97DTKB
Страница 42: ...1 12 4 AV 2 5 Schematic Diagram E2J70SCAV2 NOTE BOARD MEANS PRINTED CIRCUIT BOARD ...
Страница 43: ...1 12 5 E2J70SCAV3 AV 3 5 Schematic Diagram NOTE BOARD MEANS PRINTED CIRCUIT BOARD ...
Страница 44: ...1 12 6 E2J70SCAV4 AV 4 5 Schematic Diagram NOTE BOARD MEANS PRINTED CIRCUIT BOARD ...
Страница 45: ...1 12 7 E2J70SCAV5 AV 5 5 Schematic Diagram NOTE BOARD MEANS PRINTED CIRCUIT BOARD ...
Страница 53: ...1 12 15 DVD HDD MAIN 6 7 Schematic Diagram E2J70SCD6 NOTE BOARD MEANS PRINTED CIRCUIT BOARD ...
Страница 55: ...1 12 17 NOTE BOARD MEANS PRINTED CIRCUIT BOARD BOARD AV Top View BE2J70F01011A ...
Страница 65: ...1 15 3 R4NTI Push close 0 08 V 0 02 s Push Close detection Threshold level ...