background image

3

REMOTE CONTROL A-B SELECTION

13

POWER-SELECTION AND SILENT 
OPERATION (OUTDOOR UNIT)

14

To separate using of remote control for each indoor unit in 
case of 2 air conditioners are installed nearly. 

Remote Control B Setup. 

1. Press RESET button on the indoor unit to turn the air 

conditioner ON for Hi-wall type or press and hold MODE 
button on the indoor unit more than 20 seconds for 
Bi-

fl

ow console type. (Please follow the instructions in the 

air conditioner owner’s manual.) 

2. Point the remote control at the air conditioner. 
3. Push and hold 

 button on the Remote Control by 

the tip of the pencil. “00” will be shown on the display. 
(Picture 

1

)

4. Press 

 during pushing 

. “B” will show on the 

display and “00” will disappear and the air conditioner will 
turn OFF. The Remote Control B is memorized.
(Picture 

2

)

Note:

 1. Repeat above step to reset Remote Control to be A. 

 

2. Remote Control A has not “A” display. 

 

3. Default setting of Remote Control from factory is A.

1

2

Power-Selection (

)

This function is used when the circuit breaker is shared with 
other electrical appliances. It limits the maximum current 
and power consumption to 100%, 75%, or 50% and can be 
implemented by POWER-SELECTION. The lower percentage, 
the higher saving and also longer compressor lifetime.

Note

:  

•  When the level is selected, POWER-SEL level 

fl

ashes on 

remote LCD display for 3 seconds.
In case of 75% and 50% level, number “75” or “50” also 

fl

ashes for 2 seconds.

•  Due to the reason that POWER-SELECTION function 

limits the maximum current, inadequate cooling or 
heating capacity may occur.

Silent Operation (

)

Keep outdoor unit operating silently to ensure either yourself 
or neighborhood will have a tight sleep in nighttime. By this 
feature, the heating capacity will be optimized to deliver such 
silent experience. The silent operation can be selected from 
one of two purposes (Silent 1 and Silent 2).
There are three setting parameters: Standard level > Silent 1 
> Silent 2

Silent 1:

Though operating silently, the Heating (or Cooling) capacity 
is still prioritized to ensure having suf

fi

cient comfort inside the 

room.
This setting is a perfect balance between the Heating 
(or Cooling) capacity and the Sound level of outdoor unit.

Silent 2:

Compromising the Heating (or Cooling) capacity to the Sound 
level in any circumstance where the outdoor unit’s sound level 
is highly prioritized.
This setting has a purpose to reduce the maximum sound level 
of outdoor unit by 4 dB(A).

WEEKLY TIMER OPERATION

15

How to set WEEKLY TIMER

1.  Press 

 to enter WEEKLY TIMER 

setting.

Blink

2.  Press 

 to select desired day in 

sequence.
The sequence of day symbol appears on the 
LCD.

  

SU 

t

 MO 

t

 TU 

t

 WE 

t

 TH 

t

 FR 

t

 SA

WEEKLY SUMO

TUWETHFRSA

(All day)

3. Press 

 to select the program number. 

•  The program 1 is ready for setting while 

 is pressed PG-1 appears on the 

LCD. 

• Press 

 to change the program 

number in the sequence program 1 to 
program 4.

 

PG-1
PG-  2
PG-    3
PG-      4

  

4.  Press 

 or 

 to select the desired 

time.
•  The time can be set between 0:00 and 23:50 

in 10 minute intervals.

•  Press and hold the button to change setting 

time for 1 hr.

•  Only one of ON or OFF timer can be set on 

each program.

ON timer display

OFF timer display*

* OFF timer is used to stop the air conditioner 

only. The display does not show Operation 
mode, Temperature, Fan speed and others.

Note

:  

•  While activating of Silent operation, inadequate heating 

(or cooling) capacity may occur.

Power-Selection and Silent Operation (Outdoor Unit)

[100%]

[75%]

[50%]

SILENT#2

SILENT#1

Содержание RB-RXS33-E

Страница 1: ...WIRELESS CONTROLLER OPERATION MANUAL For general public use RB RXS33 E ENGLISH 1112150138 ...

Страница 2: ...1 5 ECO OPERATION 1 6 TIMER OPERATION 1 7 PRESET OPERATION 2 8 FIREPLACE AND 8 C HEATING OPERATION 2 9 COMFORT SLEEP OPERATION 2 10 FILTER RESET 2 11 HADA CARE FLOW OPERATION 2 12 DISPLAY LAMP BRIGHTNESS ADJUSTMENT 2 13 REMOTE CONTROL A B SELECTION 3 14 POWER SELECTION AND SILENT OPERATION OUTDOOR UNIT 3 15 WEEKLY TIMER OPERATION 3 ...

Страница 3: ...ure will increase automatically 1 degree by 2 hours maximum 2 degrees increase For heating operation the internal set temperature will decrease Set the timer when the air conditioner is operating Setting the ON Timer Setting the OFF Timer 1 Press Set the desired ON timer Press Set the desired OFF timer 2 Press Set the timer Press Set the timer 3 Press Cancel the timer Press Cancel the timer Settin...

Страница 4: ...low and automatically turn OFF Except in DRY mode and Fan only mode 1 Press Select 1 3 5 or 9 hrs for OFF timer operation 2 Press to cancel the comfort sleep operation Note The cooling operation the set temperature will increase automatically 1 degree hour for 2 hours maximum 2 degrees increase For heating operation the set temperature will decrease Firstly turn off the circuit breaker FILTER lamp...

Страница 5: ...ourself or neighborhood will have a tight sleep in nighttime By this feature the heating capacity will be optimized to deliver such silent experience The silent operation can be selected from one of two purposes Silent 1 and Silent 2 There are three setting parameters Standard level Silent 1 Silent 2 Silent 1 Though operating silently the Heating or Cooling capacity is still prioritized to ensure ...

Страница 6: ... then it will return to the WEEKLY TIMER function 3 During WEEKLY TIMER operation all of operation such as MODE TEMP FAN Hi POWER ECO and etc can be adjusted but when the clock reaches the program setting the operation will return to the set items in the program 4 When the remote control is sending a signal to the air conditioner avoid interference from objects that can block the signal Edit Weekl...

Страница 7: ...AND CO LTD Address city country 144 9 MOO 5 BANGKADI INDUSTRIAL PARK TIVANON ROAD TAMBOL BANGKADI AMPHUR MUANG PATHUMTHANI 12000 THAILAND Name of the Importer Distributor in EU TOSHIBA CARRIER UK LTD Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom ...

Отзывы: