PRESET OPERATION

7

FIREPLACE AND 8°C HEATING OPERATION

8

COMFORT SLEEP OPERATION

9

FILTER RESET

10

HADA CARE FLOW OPERATION

11

DISPLAY LAMP BRIGHTNESS ADJUSTMENT

12

Set your preferred operation for future use. The setting will 
be memorized by the unit for future operation (except air

fl

ow 

direction). 

1. Select your preferred operation. 
2. Press and hold 

 until stop blinking and the 

P

 

mark displays. 

3. Press 

 : Operate the preset operation.

Fireplace Operation (

)

Keep indoor unit’s fan blowing continuously during thermo off, 
to circulate heat from other sources over the room. 
There are three setting parameters: 
Default setting > Fireplace 1 > Fireplace 2

Fireplace 1:

During thermo off period, the indoor unit’s fan will continue to 
run by the same speed, previously selected by end-user.

Fireplace 2:

During thermo off period, the indoor unit’s fan will continue to 
run at super-low speed, programmed from factory.

8°C Heating Operation (8°C)

Heat mode operation for keep room temperature (5-13°C) with 
less of energy usage.

Fireplace and 8°C Heating Operation

8°C

FIREPLACE 1

FIREPLACE 2

Normal 

operation

Note

:  

•  While Fireplace operation on heating mode, indoor unit 

fan always runs and cold air breezing might be occurred.

•  Fireplace and 8°C will operate in Heating mode only.

For comfortable sleep, automatically control air 

fl

ow and 

automatically turn OFF (Except in DRY mode and Fan only 
mode). 

1. Press 

: Select 1, 3, 5 or 9 hrs for OFF timer 

operation. 

2. Press 

 to cancel the comfort sleep operation. 

Note:

   The cooling operation, the set temperature will increase 

automatically 1 degree/hour for 2 hours (maximum 
2 degrees increase). For heating operation, the set 
temperature will decrease.

Firstly, turn off the circuit breaker. 

FILTER lamp lights on; the 

fi

lter must be cleaned. 

To turn off the lamp, press RESET button on the indoor unit 
for Hi-wall or ON/OFF button for Bi-

fl

ow console, also can 

push the FILTER button on the remote control in another way. 
(Please follow the instructions in the air conditioner owner’s 
manual.)

HADA CARE FLOW

Air 

fl

ow upward to the ceiling, provide Indirect air 

fl

ow to body 

and homogenize room temperture.

HADA CARE FLOW operation

Press 

  For start and stop HADA CARE FLOW

Cancel

HADA CARE FLOW

HADA CARE FLOW

Note

:

•  During HADA CARE FLOW mode, FIX and SWING 

button cannot active

To decrease the display lamp brightness or turn it off.

1. Press and hold 

)$1

 for 3 seconds until brightness 

level (

 or 

) is shown on remote control LCD 

then release the button.

2. Press 

Rise

 or 

Decrease

 to adjust brightness 

in 4 levels.

Remote 

control LCD

Operation display

Brightness

 

Lamp illuminates full brightness.

100%

Lamp illuminates 50% 
brightness.

50%

Lamp illuminates 50% 
brightness and the operation 
lamp is turned off.

50%

All lamps are turned off.

All turned 

off

•  In the examples of 

 and 

, the lamp illuminates for 5 

seconds before going off.

Содержание RB-RXS33-E

Страница 1: ...WIRELESS CONTROLLER OPERATION MANUAL For general public use RB RXS33 E ENGLISH 1112150138 ...

Страница 2: ...1 5 ECO OPERATION 1 6 TIMER OPERATION 1 7 PRESET OPERATION 2 8 FIREPLACE AND 8 C HEATING OPERATION 2 9 COMFORT SLEEP OPERATION 2 10 FILTER RESET 2 11 HADA CARE FLOW OPERATION 2 12 DISPLAY LAMP BRIGHTNESS ADJUSTMENT 2 13 REMOTE CONTROL A B SELECTION 3 14 POWER SELECTION AND SILENT OPERATION OUTDOOR UNIT 3 15 WEEKLY TIMER OPERATION 3 ...

Страница 3: ...ure will increase automatically 1 degree by 2 hours maximum 2 degrees increase For heating operation the internal set temperature will decrease Set the timer when the air conditioner is operating Setting the ON Timer Setting the OFF Timer 1 Press Set the desired ON timer Press Set the desired OFF timer 2 Press Set the timer Press Set the timer 3 Press Cancel the timer Press Cancel the timer Settin...

Страница 4: ...low and automatically turn OFF Except in DRY mode and Fan only mode 1 Press Select 1 3 5 or 9 hrs for OFF timer operation 2 Press to cancel the comfort sleep operation Note The cooling operation the set temperature will increase automatically 1 degree hour for 2 hours maximum 2 degrees increase For heating operation the set temperature will decrease Firstly turn off the circuit breaker FILTER lamp...

Страница 5: ...ourself or neighborhood will have a tight sleep in nighttime By this feature the heating capacity will be optimized to deliver such silent experience The silent operation can be selected from one of two purposes Silent 1 and Silent 2 There are three setting parameters Standard level Silent 1 Silent 2 Silent 1 Though operating silently the Heating or Cooling capacity is still prioritized to ensure ...

Страница 6: ... then it will return to the WEEKLY TIMER function 3 During WEEKLY TIMER operation all of operation such as MODE TEMP FAN Hi POWER ECO and etc can be adjusted but when the clock reaches the program setting the operation will return to the set items in the program 4 When the remote control is sending a signal to the air conditioner avoid interference from objects that can block the signal Edit Weekl...

Страница 7: ...AND CO LTD Address city country 144 9 MOO 5 BANGKADI INDUSTRIAL PARK TIVANON ROAD TAMBOL BANGKADI AMPHUR MUANG PATHUMTHANI 12000 THAILAND Name of the Importer Distributor in EU TOSHIBA CARRIER UK LTD Address city country Porsham Close Belliver Industrial Estate PLYMOUTH Devon PL6 7DB United Kingdom ...