– 16 –
EN
EN
ID
5-4. Self clean operation mode
This function is provided to dry the inside of the indoor unit by the FAN operation after running the
cooling / dry / Auto (cooling) mode to keep the indoor unit clean.
• The self clean operation time varies with the cooling / dry / AUTO (cooling) operation time as follows.
Cooling / dry / AUTO (cooling) operation time
Self clean operation time
Less than 10 minutes
No self clean operation
10 minutes to less than 1 hour
1 hour
More than 1 hour
2 hours
• “ ” is displayed on the remote controller during self clean operation.
To stop self clean operation forcibly, push
button twice in succession.
CAUTION
• The fan continues to run even after
button is pushed to stop operation in some modes.
This is normal because the self clean operation mode is in progress.
• The louvers open slightly and are directed horizontally during self clean operation, and they close when the
self clean operation is completed.
• The operation lamp (LED) does not light during the self clean operation mode (function).
• The self clean operation mode (function) cannot clean the room or remove the already existing mold and dust
inside the indoor unit.
• To cancel the self clean operation function, consult the dealer.
6
Limited operation by twin and group
combination
NOTE
• Twin combination
The combination where 2 indoor units are installed for 1 outdoor unit.
• Group combination
Operate air conditioners in more than one system (such as single combination and twin combination) in same
time.
• Header unit
The representative unit during twin and group operation. Receive commands from remote controller and
transmit the commands to follower units.
(The header unit is indoor unit that receives START / STOP signal from the wireless remote controller.)
• Follower unit
Indoor units other than the header unit are called follower unit.
Example of twin combination
Indoor
Outdoor
Outdoor
Outdoor
Control line
Other connecting line
Outdoor
Indoor
Remote
controller
Remote
controller
Indoor
Indoor
Indoor
Example of group combination
CAUTION
When using indoor unit in group control,
1. Hi POWER operation will not function.
When Hi POWER is transmitted from wireless remote controller the receiving sound will be heard from the
indoor unit and display on the wireless remote controller will also change. However, the indoor unit does not
operate Hi POWER operation. Restore the display on the wireless remote controller pushing Hi-POWER
button.
2. COMFORT SLEEP
When COMFORT SLEEP is transmitted from wireless remote controller, the receiving sound will be heard
from the indoor unit and the display on the wireless remote controller will also be changed as same as Hi
POWER operation. However, the set temperature and the fan speed will not be automatically adjusted. Only
off timer function is activated.
3. Units other than the Header unit cannot be operated with remote controller and the TEMPORARY
operation.
When operating air conditioner with wireless remote controller transmission should be sent to the Header unit.
Header and follower indoor units are decided through address setting upon installation. Follower unit will not
receive any signals from wireless remote controller.
Air conditioner will not work even if the
button on the follower unit is pressed.
(Some Follower units may receive SWING and FIX, but these operations are performed only on the unit that
received the signal.) (When wireless remote controller is used, only the Header unit receives SWING signal.
If the SWING signal is transmitted to follower unit, the sound to refuse receiving signal (3 beeps) is heard and
the follower unit does not receive the signal.
For FIX operation, both Header and follower unit perform the operation by itself.
When wired remote controller is used, airflow direction can be changed on each unit by selecting the indoor
unit.)
4. TIMER lamp lights up only on the Header unit.
When the timer is set with wired remote controller, even the TIMER lamp on the Header unit will not light up.
31-EN