
– 1
7
–
1. SPECIFICATIONS
1-1. Outdoor Unit
<Digital Inverter>
Model name
Outdoor unit
RAV-GM
301AT*P*
401AT*P*
Power supply
1 phase 220-240V, 50Hz
1 phase 220V, 60Hz
Compressor
Type
Rotary
D
C Invertor
Motor
(kW)
0
.
75
1
.
1
Pole
4
4
Refrigerant charged
(kg)
0
.
63
0.90
Refrigerant control
Pulse motor valve
Inter
connecting pipe
Standard length
(m)
7.5
7.5
Min. length
(m)
2
.0
2
.0
Max. total length
(m)
20
20
Additional refrigerant charge
under long piping connector
20g/m
(
15
m to
20
m)
20
g/m
(
15
m to
20
m)
Height
difference
Outdoor lower
(m)
10
10
Outdoor higher
(m)
10
10
Outer dimension
Height
(mm)
550
550
Width
(mm)
780
780
Depth
(mm)
290
290
Appearance
Silky shade (Muncel 1Y8.5/0.5)
Total weight
(kg)
29
34
Heat exchanger
Finned tube
Fan unit
Fan
Propeller fan
Standard air flow high
(m3/min.)
30
37
Motor
(W)
43
43
Connecting pipe
Gas side
(mm)
9
.
5
12
.
7
Liquid side
(mm)
6.4
6
.
4
Sound pressure level
Cooling/Heating (dB·A)
46/4
7
4
9
/5
0
Sound power level
Cooling/Heating (dB·A)
61
/
62
64
/
65
Outside air temperature, Cooling
°C (Dry bulb temp.)
46 to -
1
5
Outside air temperature, Heating
°C (Wet bulb temp.)
24
to -15
SVM-13072.indb 14
SVM-13072.indb 14
11/01/13 1:53 PM
11/01/13 1:53 PM
FILE NO. SVM-18042
Содержание RAV-GM301ATJP-E
Страница 20: ... 20 2 CONSTRUCTION VIEWS EXTERNAL VIEWS 2 1 RAV GM301AT P GM401AT P FILE NO SVM 18042 ...
Страница 24: ... 24 4 WIRING DIAGRAM 4 RAV GM301AT P GM401AT P FILE NO SVM 18042 ...
Страница 100: ...144 9 MOO 5 BANGKADI INDUSTRIAL PARK TIVANON ROAD TAMBOL BANGKADI AMPHUR MUANG PATHUMTHANI 12000 THAILAND ...