No.
Part name
Procedure
Remarks
"
Heat
exchanger
1. How to remove the frame of heat
exchanger
1) Recover the refrigerant gas.
2) Proceed 1 of
1
,
2
,
3
,
4
.
3) Take off TO-sensor.
4)
2. How to attach the assembly of heat
exchanger (maintenance part)
1) Proceed through the reverse order of
how to remove
※
The pipe fixing plate and pipe cover
that come with the assembly of heat
exchanger, before replacement, are just
for shipping. There is no need to attach
them.
However, make sure to fasten a screw
that attach the pipe fixing plate (ST1T
Ø4 × 10,
1
pc
s
.) to the assembly of
heat exchanger, after replacement.
NOTES:
※
Don't remove the cap from the joint of the
assembly of heat exchanger (maintenance
part) till you braze. And don't neglect the
assembly of heat exchanger (maintenance
part) without cap for a long time.
TO sensor
5)
6)
Using a burner remove the
discharge pipe connected to the
ASM-COND.
Take off
screws between the
assembly of heat exchanger and the
partition board. and SUB
PARTITION.(ST1T Ø4 × 10,
5
pcs.)
Take off
screws between the
assembly of heat exchanger and the
bottom plate.(ST1T Ø4 × 1
0, 2
pcs.
7) Pull the back side of the assembly
of heat exchanger.
Take off piping from
ASM-
C
OND
Screw
SCREW
Screw
- 96 -