How to Install Indoor Unit

1. Remove the air inlet grille. Open the air inlet grille and remove the strap.
2. Remove the front panel (Remove the 4 screws).

NOTE

  The hole should be made at a slight downward slant on the outdoor side.

Shield pipe

Drain hose

Extension drain hose

Inside the room

2. Put water in the drain pan and make sure that the water is drained out of 

doors.

3. When connecting extension drain hose, insulate the connecting part of 

extension drain hose with shield pipe.

CAUTION

Arrange the drain pipe for proper drainage from the unit.
Improper drainage can result in dew-dropping.

Front panel

Air inlet grille

Hook

Treatment of piping connection

1) Check the fl are nut connections for the gas leak with a gas leak detector 

or soap water.

2) To prevent gap in slit, fasten top and bottom with tape.
3) Slit is covered with tape.
4) Fasten with supplied Insulate sheet to prevent gap on the top of slit.

Gas leak check

Tape

Slit

9

 Insulation sheet

Do not rise the
drain hose.

Do not form the 
drain hose into 
a wavy shape.

Do not put the 
drain hose end 
into water.

Do not put the 
drain hose end in 
the drainage ditch.

Drainage

1. Run the drain hose sloped downwards.

Wiring connection

Wiring of the connection cable is necessary to remove the front panel.

1. Remove the terminal cover and cord clamp.
2. Insert the connecting cable (according to the local rule) into the pipe hole 

on the wall.

3. Take out the connecting cable through the cable slot on the rear panel so 

that it protrudes about 50 cm from the front.

4. Insert the connecting cable fully into the terminal block and secure it 

tightly with screws.

5. Tightening torque : 1.2 N·m (0.12 kgf·m)
6. Secure the connecting cable with the cord clamp.
7. Fix the terminal cover, install the front panel and grille inlet.

CAUTION

  Be sure to refer to the wiring system diagram labeled inside the front 

panel.

  Check local electrical cords and also any specifi c wiring instructions or 

limitations. 

110 mm

20 mm

10 mm

50 mm 

NOTE

  Use stranded wire only.

  Wire type  :  H07RN-F or 60245 IEC66 (1.0 mm

2

 or more) 

Stripping length of the connecting cable

Terminal 
block

Earth line

Screw

Cord clamp

Earth screw

Earth line

Screw

Terminal cover

Hook

Layout of connection piping

Connection piping

430 mm

Tape

8

Содержание RAS-B10U2FVG-E

Страница 1: ...AIR CONDITIONER SPLIT TYPE INSTALLATION MANUAL Indoor unit RAS B10 13 18U2FVG E R32 1112151199 ...

Страница 2: ...tallation Parts 6 INDOOR UNIT 7 Installation Place 7 Cutting a Hole and Mounting Installation Plate 7 How to Install Indoor Unit 8 Concealed Installation 9 OTHERS 10 Gas Leak Test 10 Setting of Remote Control Selector Switch 10 Remote Control A B Selection 10 Test Operation 10 Auto Restart Setting 10 EN ...

Страница 3: ...e of appliance use shall be at least polychloroprene sheathed flexible cord design H07RN F or cord designation 60245 IEC66 Shall be installed in accordance with national wiring regulations CAUTION This appliance must be connected to the main power supply by means of a circuit breaker or a switch with a contact separation of at least 3 mm in all poles DANGER FOR USE BY QUALIFIED PERSONS ONLY TURN O...

Страница 4: ...ght of the unit Personal injury and property damage can result if the unit falls Before doing the electrical work attach an approved plug to the power supply cord Also make sure the equipment is properly earthed Appliance shall be installed in accordance with national wiring regulations If you detect any damage do not install the unit Contact your dealer immediately Do not use any refrigerant diff...

Страница 5: ... is the refrigerant charge amount in appliance in kg h0 is the installation height of the appliance in m 0 6 m for floor standing 1 8 m for wall mounted 1 0 m for window mounted 2 2 m for ceiling mounted For these units recommend installation height 1 0 m or less Comply with national gas regulations CAUTION Exposure of unit to water or other moisture before installation could result in electric sh...

Страница 6: ...ation is not accepted by the supplier the service agency will take adequate countermeasures Important information regarding the refrigerant used This product contains fluorinated greenhouse gases Do not vent gases into the atmosphere Refrigerant type R32 GWP 1 value 675 ex R32 ref AR4 1 GWP global warming potential The refrigerant quantity is indicated on the unit name plate This value is based on...

Страница 7: ...ille Filter Maintenance Shelf life Clean every 3 6 months when dust tuck or covers the filter 1 Recommend to use vacuum to clean by sucking the dusts which stick or dip inside the filter or use the blower to blow the dust go out through the filter 2 If necessary to use water to clean simply use the plain water to wash the filter dry with the sunlight for 3 4 hours or until it completely dry Nevert...

Страница 8: ...ol holder Do not allow the drain hose to get slack Make sure to run the drain hose sloped downward The auxiliary piping can be connected to the left rear left rear right right bottom right or bottom left Insulate the refrigerant pipes separately with insulation not together 8 mm thick heat resisting polyethylene foam Cut the piping hole sloped slightly Right Rear right Left Bottom right Rear left ...

Страница 9: ...hole brim ring sold separately A place which provides the spaces around the indoor unit as shown in the diagram A place where there are no obstacles near the air inlet and outlet A place which allows easy installation of the piping to the outdoor unit A place which allows the front panel to be opened In case of block brick concrete or similar type walls make 5 mm holes in the wall Insert clip anch...

Страница 10: ... Do not form the drain hose into a wavy shape Do not put the drain hose end into water Do not put the drain hose end in the drainage ditch Drainage 1 Run the drain hose sloped downwards Wiring connection Wiring of the connection cable is necessary to remove the front panel 1 Remove the terminal cover and cord clamp 2 Insert the connecting cable according to the local rule into the pipe hole on the...

Страница 11: ...or more 20 to 30 240 to 250 Floor Wall Side view Unit mm 4 In case of lattice establishment Follow the following figure make sure to keep enough distance between lattice frame and wall Be sure to switch to wall burying mode The lattice should be make of wood Between the air inlet and outlet should be devided with partition board Be sure to establish the open part for RECEIVER The open part of latt...

Страница 12: ...y Remote Control B Setup 1 Push and hold button on the Remote Control by the tip of the pencil 00 will be shown on the display Picture 1 2 Press during pushing B will show on the display and 00 will disappear and the air conditioner will turn OFF The Remote Control B is memorized Picture 2 Note 1 Repeat above step to reset Remote Control to be A 2 Remote Control A has not A display 3 Default setti...

Страница 13: ...1112151199 ...

Отзывы: