2-2
-1
.
SUMMARIES OF PRODUCT CHARACTERISTICS
RAS-
4
M
27
S3AV-A
T
KHVHDLUFRQGLWLRQHUVDUHFRPPRGLWLHVIRU'5(''HPDQG5HVSRQVH(QDEOLQJ'HYLFHWKDWFRPSOLHVZLWK
AS/NZS 4755.3.1.
N
L
COM DRM1 DRM2 DRM3
1 2 3
COM DRM1 DRM2 DRM3
MCC-1653
DRED
Demand response interface
Trans-
former
Outdoor control
P.C. board
CN101
CN102
CN100
CN105
Locally procured
Power supply
Indoor (A~
D
) unit
Connecting
Cord clamp
DRED terminal block connections
Banding band
These models supports DRM1 DRM2 DRM3.
*1: E30m = total electrical energy (kWh) used by the air conditioner for all purposes (including compressors,
controls and fans) over a 30 min period.
*2: R = rated input electrical power of the air conditioner (kW) at rated capacity in the mode in which it is
operating during the demand response event (i.e.cooling or heating).
DRED installation position
Outline of DRED wiring
AS/NZS 4755
DRM1
DRM2
DRM3
Demand response mode
DRM1
DRM2
DRM3
Description
Compressor off
E30m
≤
R × 0.50 × 0.5
E30m
≤
R × 0.75 × 0.5
FILE NO. SVM-15073
- 6 -