– 66 –
9-2-2. Installation Place
• A place which provides the spaces around the
indoor unit as shown in the installation diagram.
• A place where there is no obstacle near the air
inlet and outlet.
• A place which allows an easy installation of the
piping to the outdoor unit.
• A place which allows the front panel to be opened.
CAUTION
• Direct sunlight to the indoor unit wireless
receiver should be avoided.
• The microprocessor in the indoor unit should
not be too close to r-f noise sources.
Remote controller
• A place where there are no obstacles such as a
curtain that may block the signal from the remote
controller.
• Do not install the remote controller in a place
exposed to direct sunlight or close to a heating
source, such as a stove.
• Keep the remote controller at least 1 m apart from
the nearest TV set or stereo equipment.
(This is necessary to prevent image disturbances
or noise interference.)
• The location of the remote controller should be
determined as shown below.
Fig. 9-2-1
9-2-3. Cutting a Hole and Mounting
Installation Plate
Cutting a Hole
7m
Fig. 9-2-2
1. After determining the pipe hole position with the
mounting plate (80 mm
), drill the pipe hole
(Ø65 mm) at a slight downward slant to the
outdoor side.
NOTE
• When drilling the wall that contains a metal lath,
wire lath or metal plate, be sure to use a pipe hole
brim ring sold separately.
• There may be a wire conduit embedded in the
wall. Chec on the blueprint or ask the builder
whether it is done or not.
• Make sure of the proper installation of the
installation plate before mounting the indoor unit.
Mounting the Installation Plate
For installation of the indoor unit, use the paper
pattern on the back.
Fig. 9-2-3
The center of the piping slot
is above the arrow.
The center of the pipe
hole is above the arrow.
80mm
Pipe hole
65m
m
40.5 mm
Indoor unit
Pipe
hole
65.5mm
120mm
Thread
Weight
1
Installation
plate
9 Mounting
screw
Pipe hole
65.5mm
40mm
Anchor bolt hole
66mm