12
EN
1.
Remove the side panel and cord clamp from the outdoor unit.
2.
Connect the connecting cable to the terminal as identified by the matching numbers on the terminal block of indoor and outdoor
unit.
3.
Insert the power cord and the connecting cable fully into the terminal block and secure it tightly with screws.
4.
Use vinyl tape, etc. to insulate the cords which are not going to be used. Locate them so that they do not touch any electrical or
metal parts.
5.
Secure the power cord and the connecting cable with the cord clamp.
6.
Attach the side panel on the outdoor unit.
Stripping length of connecting cable
4 unit (A + B + C + D) Multi
3 unit (A + B + C) Multi
Wiring Connection
Model
4 unit Multi
3 unit Multi
4 unit Multi
RAS-
4M23SAV-E
RAS-
4M23SACV-E
RAS-
3M26GAV-E1
RAS-
4M27GAV-E1
RAS-
4M27GACV-E
Power source
220–240V ~50Hz
220V ~60Hz
Maximum running current
13.8 A
13.8 A
16.4 A
17.0 A
16.6 A
Installation fuse rating
16 A breaker or fuse
(all types can be used)
20 A breaker or fuse
(all types can be used)
Power cord
H07RN–F or 60245IEC66 (1.5 mm
2
)
H07RN–F or 60245IEC66 (2.5 mm
2
)
Connecting cable
H07RN–F or 60245IEC66 (1.0 mm
2
)
H07RN–F or 60245IEC66 (1.0 mm
2
)
CAUTION
• Incorrect wiring connection may cause electrical parts to burn out.
• Be sure to comply with local regulations/codes when running the wire from outdoor unit to indoor unit. (Size of wire and wiring
method etc.)
• Every wire must be securely connected.
• If incorrect or incomplete wiring is carried out, fire or smoke may result.
• Prepare the power supply for the exclusive use of the air conditioner.
30
30
10
L N
10
1 2 3
10
10
40
40
Earth line
Connecting
cable
Power cord
Earth line
Terminal block (Connecting cable)
Screw
Connecting cable
(A unit)
Power cord
Connecting cable
(B unit)
Connecting cable
(C unit)
Connecting cable
(D unit)
Terminal block (Connecting cable)
Screw
Connecting cable
(A unit)
Power cord
Connecting cable
(B unit)
Connecting cable
(C unit)
Содержание RAS-3M26GAV-E1
Страница 18: ...EG21808701 ...