Item
Operation flow and applicable data, etc.
Description
1
5
. Remote-A or B
selection
Mode
1
6
. Hi-POWER
1.
Purpose
This operation is to operate only one
indoor unit using one remote controller.
2.
Description
When operating one indoor unit in a
situation where two indoor units have
been installed in the same room or
nearby rooms, this operation prevents
the remote controller signal from being
received simultaneously by both units,
thus preventing both units from
operating.
3.
Operation
The indoor unit on which the remote
controller selection has been set to B
receives the signal of the remote
controller also set to B.
(At the factory the remote controller
selection is set to A on all the indoor
units. There is no A setting display.)
Setting the remote controller
To separate using of remote control for each indoor
unit in case of 2 air conditioner are installed nearly.
Remote Control B Setup.
1
2
1.
2.
3.
Press RESET button on the indoor unit to turn the
air conditioner ON.
Point the remote control at the indoor unit.
Push and hold button on
back side of
Remote Control
.
“00” will be shown on the display. (Picture )
4.
.“B” will show on
MODE
Press during pushing
1
the display and “00” will disappear and the air
conditioner will turn OFF. The Remote Control B
is memorized. (Picture )
2
Note
: 1. Repeat above step to reset Remote Control
to be A.
2. Remote Control A has not "A" display.
3. Default setting of Remote Control from
factory is A.
([Hi-POWER]
Feature set from
MENU
button
When [Hi-POWER]
Feature
is
select
while the
indoor
unit is in Auto, Cooling or Heating operation,
Hi-P mark is indicated on the display of the remote
controller and the unit operates as follows.
1. Automatic operation
•
The indoor unit operates in according to the
current operation.
2. Cooling operation
•
The preset temperature drops 1ºC
(The value of the preset temperature on the
remote controller does not change.)
The indoor unit's fan speed level increase 1 tap
3. Heating operation
•
The preset temperature increases 2ºC
(The value of the preset temperature on the
remote controller does not change.)
The indoor unit's fan speed level increase 1 tap
4. The Hi-POWER mode can not be set in Dry
operation
- 42 -