80
−
FILE NO. SVM-04032
10-2 Outdoor Unit (RAS-18UAH-E3)
1) Stop the operation of the air conditioner and turn off
its main power supply or remove the power supply
cord.
2) Remove the electrical parts cover.
(4 screws
∅
4 x 10L)
3) Remove 2 cord clamps (4 screws
∅
4 x 22L) and
disconnect the power supply cord and connecting
cable after removing 6 screws on the terminal block
and 1 ground screw on the electrical parts base.
4) Remove the front cabinet. (8 scerws
∅
4 x 10L)
(Pull the front lower portion toward you, and pull out
it upward to remove it.)
5) Remove the side cabinet. (8 screws
∅
4 x 10L)
1) Perform the common procedure
1
2) Remove the capacitor band. (1 screw
∅
4 x 10L)
3) Disconnect the lead wires from the capacitor
terminal.
1) Perform the common procedure
1
2) Remove the fixing screw. (1 screw
∅
4 x 10L)
3) Disconnect the lead wires from the capacitor
terminal.
1) Perform the common procedure
1
2) Remove the fixing screw (2 screw
∅
4 x 16L)
3) Disconnect the lead wires from the terminal.
1) Perform the common procedure
1
2) Remove the fixing screw. (2 screws
∅
4 x 10L)
3) Disconnect the housing from the P.C. Board.
1) Perform the common procedure
1
2) Disconnect the lead wires from the P.C. Board.
3) Remove P.C. Board after unhooking 4 clams.
1
Common
procedure
2
Running
capacitor
for compressor
3
Running
capacitor
4
Magnetic contactor
5
Transformer
6
P.C. Board
No.
Part name
Procedures
Remarks
Remove
8 screws Ø4 x 10L
4 screws Ø4 x 22L
4 screws Ø4 x 10L
Running capacitor
for compressor
Running capacitor
for fan motor
P.C. Board
Magnetic contactor
Transformer