– 5 –
FILE NO. SVM-04032
1-2
RAS-24UFP-E
3
/24UA-E
3
RAS-24UFHP-E
3
/24UAH-E
3
RAS-24UFPX
3
/24UAX
3
RAS-24UFPX
3
-T/24U
AX3-T
Cooling
Heating
Cooling
Capacity
kW
220V
240V
220V
240V
220V
240V
220V
6.30 6.30 6.80 6.90 6.40 6.45 6.10
Phase
1
∅
Power source
V
220 – 240
220
Hz
50
Power consumption
W
2480
2650
2490
2670
2260
2400
2260
Power factor
%
97
90
97
89
91
84
91
Running current
Indoor
A
0.45
0.45
0.45
0.45
0.45
0.45
0.45
Outdoor A 11.15 11.85 11.20 12.00 10.50 10.80 10.50
Starting current
A
60
55
Moisture removal
lit/h
2.5
2.7
Noise
Indoor (H/M/L)
dB
46/42/37
Outdoor
dB
56
57
57
58
56
57
56
Refrigerant
Name of refrigerant R-22
Rated amount kg
Refrigerant control
Capillary tube
Gas side size
mm
∅
15.88
Connection type
Flare connection
Liquid side size
mm
∅
6.35
Interconnection
Connection type
Flare connection
pipe
Maximum length
m
15*
1
(One way)
25*
2
Maximum height
m
10
difference
INDOOR UNIT RAS-24UFHP-E3 RAS-24UFPX3-T
RAS-24UFPX3
Width
mm
1093
Dimensions
Height
mm
633
Depth
mm
208
Net weight
kg
23
Evaporator type
Finned tube
Indoor fan type
Multi blade fan
High fan
m
3
/h
900
930
900
Air volume
Medium fan
m
3
/h
750
760
750
Low fan
m
3
/h
650
660
650
Fan motor output
W
50
Air filter
Washable -filter
OUTDOOR UNIT RAS-24UAH-E3 RAS-24UAX3-T
RAS-24UAX3
Width
mm
880
Dimensions
Height
mm
690
Depth
mm
310
Net weight kg 64 58
Condenser type
Finned tube
Outdoor fan type
Propeller fan
Airflow volume
m
3
/h
3380
3560
3380
3560
3380
3560
3380
Fan motor output
W
65
Compressor
Model PH310X3-4MM 2JS386D5BB02
Output W 2200 1800
Safety device
IOL, Td Sensor
IOL
Louver type
Automatic louver
Usable outdoor temperature range °C 15 ~ 43 –10 ~ 24 15 ~ 43
MODEL
ITEM
1.63
1.80
RAS-24UFP-E3
RAS-24UA-E3