14
Power Supply and Connecting Cable Connection
Power Supply Input at Outdoor Unit Terminal Block (Recommend)
Indoor Unit
Outdoor Unit
Connecting cable
connect to
1
2
3
Terminal block (L N 1 2 3)
Earth line
Connecting cable
Connecting cable
Stripping length of the
connecting cable
3
2
1
Earth line
50 mm
10 mm
70 mm
10 mm
Connecting cable
Earth line
Earth line
Connecting cable
Power cord
Terminal block
Power cord
Power Supply Input at Indoor Unit Terminal Block (Optional)
Indoor Unit
Outdoor Unit
Power supply cable
connect to
L
N
Terminal block (L N 1 2 3)
Earth line
Power supply
cable
Power supply cable
Stripping length of the power
supply cable
N
L
Earth line
50 mm
10 mm
70 mm
10 mm
Connecting cable
Earth line
Connecting cable
Terminal block
Connecting cable
Connecting cable
connect to
1
2
3
Terminal block (L N 1 2 3)
Earth line
Power supply
cable
Connecting
cable
Earth line
Earth line
Stripping length of the
connecting cable
3
50 mm
10 mm
70 mm
10 mm
01_1120650192-EN.indd 14
01_1120650192-EN.indd 14
12/11/2562 BE 4:43 PM
12/11/2562 BE 4:43 PM