Item
Operation flow and applicable data, etc.
Description
2
3
. Hi-POWER
([Hi-POWER] button on the remote controller
is pressed)
When [Hi-POWER] button is pressed while the indoor
unit is in Auto, Cooling or Heating operation, Hi-
Mode
POWER mark is indicated on the display of the remote
controller and the unit operates as follows.
1. Automatic operation
•
The indoor unit operates in according to the
current operation.
2. Cooling operation
remote controller does not change.)
The indoor unit's fan speed level increase 1 tap
•
The preset temperature drops 1ºC
(The value of the preset temperature on the
3. Heating operation
remote controller does not change.)
The indoor unit's fan speed level increase 1 tap
•
The preset temperature increases 2ºC
(The value of the preset temperature on the
4. The Hi-POWER mode can not be set in Dry
operation
∗
The Hi-POWER operation will be cancelled
when press [Hi-POWER] button again.
2
4
. Operation
mode
setectable
2.
1. Purpose
Choosing the operating system as
appropriate in real condition
Operation
Factory default setting prefer
"Heat pump" system. Through it is
able to cooling only system heating
only system or return to factory
default.
Operating system setting
•
•
•
Do cut J804 for cooling only system
•
Do cut J805 for heating only system
•
Do cut both of J804 and J805 for return
to factory default.
- 55 -
Содержание RAS-18J2AVSG-E
Страница 21: ...5 WIRING DIAGRAM RAS 18J2KVSG E RAS 18N4KVSG E RAS 18J2AVSG E 21 ...
Страница 22: ...RAS B22J2KVSG E RAS B22N4KVSG E RAS 22J2AVSG E 22 ...
Страница 23: ...RAS B24J2KVSG E RAS B24N4KVSG E RAS 24J2AVSG E 23 ...
Страница 143: ...144 9 MOO 5 BANGKADI INDUSTRIAL PARK TIVANON ROAD TAMBOL BANGKADI AMPHUR MUANG PATHUMTHANI 12000 THAILAND ...