Item
Operation flow and applicable data, etc.
Description
7. Defrost control
(Only in heating
operation)
(This function removes frost adhered to the outdoor
heat exchanger.)
The temperature sensor of the outdoor heat ex-
changer (Te sensor) judges the frosting status of the
outdoor heat exchanger and the defrost operation is
performed with 4-way valve reverse defrost system.
The necessity of defrost operation is
detected by the outdoor heat exchanger
temperature. The conditions to detect the
necessity of defrost operation differ in A,
B, or C zone each. (Table 1)
<Defrost operation>
• Defrost operation in A to C zones
1) Stop operation of the compressor for
20 seconds.
2) Invert (ON) 4-way valve 10 seconds
after stop of the compressor.
3) The outdoor fan stops at the same time
when the compressor stops.
4) When temperature of the indoor heat
exchanger becomes 38°C or lower,
stop the indoor fan.
<Finish of defrost operation>
• Returning conditions from defrost
operation to heating operation
1) Temperature of outdoor heat exchanger
rises to +8°C or higher.
2)Temperature of outdoor heat exchanger is
kept at +5°C or higher for 80 seconds.
3) Defrost operation continues for
15 minutes.
<Returning from defrost operation>
1) Stop operation of the compressor for
approx. 50 seconds.
2) Invert (OFF) 4-way valve approx. 40
seconds after stop of the compressor.
3) The outdoor fan starts rotating at the
same time when the compressor starts.
Start of heating operation
b,c
a
d
Table 1
Defrost zone
In normal To
In abnormal To
A zone
TE0-TE≥3°C & SH-SH0≤2
(TE0-TE)-(TO0-TO)≥3°C & SH-SH0≤2
B zone
TE0-TE≥2°C & SH-SH0≤2
(TE0-TE)-(TO0-TO)≥2°C & SH-SH0≤2
C zone
TE≤ -25°C & SH-SH0≤2
D zone
More than 90 minutes accumulate heating operation time condition TE≤ -2°C
Table 2
Heating operation
Model
(time)
18k
22k
24k
a
43
41
b
41
39
c
29
29
d
90
70
- 41 -
Содержание RAS-18J2AVSG-E
Страница 21: ...5 WIRING DIAGRAM RAS 18J2KVSG E RAS 18N4KVSG E RAS 18J2AVSG E 21 ...
Страница 22: ...RAS B22J2KVSG E RAS B22N4KVSG E RAS 22J2AVSG E 22 ...
Страница 23: ...RAS B24J2KVSG E RAS B24N4KVSG E RAS 24J2AVSG E 23 ...
Страница 143: ...144 9 MOO 5 BANGKADI INDUSTRIAL PARK TIVANON ROAD TAMBOL BANGKADI AMPHUR MUANG PATHUMTHANI 12000 THAILAND ...