INDOOR UNIT

INDOOR UNIT

Installation Place

•  Direct sunlight to the indoor unit’s wireless receiver should be avoided.
•  The microprocessor in the indoor unit should not be too close to RF 

noise sources.

  (For details, see the owner’s manual.)  

     

Remote control

•  A place where there are no obstacles such as a curtain that may block the 

signal from the indoor unit

•  Do not install the remote control in a place exposed to direct sunlight or 

close to a heating source such as a stove.

•  Keep the remote control at least 1 m apart from the nearest TV set or 

stereo equipment. (This is necessary to prevent image disturbances or 
noise interference.)

•  The location of the remote control should be determined as shown below.

Cutting a Hole and Mounting

Installation Plate

 

NOTE

•  When drilling a wall that contains a metal lath, wire lath or metal plate, be 

sure to use a pipe hole brim ring sold separately.

     

Cutting a hole

When installing the refrigerant pipes from the rear

     

Mounting the installation plate

When the installation plate is directly mounted 
on the wall

1. Securely 

fi

 t the installation plate onto the wall by screwing it in the upper and 

lower parts to hook up the indoor unit.

2.  To mount the installation plate on a concrete wall with anchor bolts, use the 

anchor bolt holes as illustrated in the below 

fi

 gure.

3.  Install the installation plate horizontally in the wall.

When installing the installation plate with a mounting screw, do not use the 
anchor bolt holes. Otherwise, the unit may fall down and result in personal 
injury and property damage.  

1.  After determining the pipe hole position on the mounting plate (

¨

), drill 

the pipe hole (Ø65 mm) at a slight downward slant to the outdoor side. 

•  A place which provides the spaces around the indoor unit as shown in the 

diagram

•  A place where there are no obstacles near the air inlet and outlet
•  A place which allows easy installation of the piping to the outdoor unit
•  A place which allows the front panel to be opened
•  The indoor unit shall be installed at least 2.5 m height. Also, it must be 

avoided to put anything on the top of the indoor unit.  

CAUTION

 

 

5

4

°

45

°

5

7

°

(Side view)

(Top view)

Indoor unit

Reception range

Remote 
control

Remote
control

Reception
range

Indoor unit

CAUTION

Failure to 

fi

 rmly install the unit may result in personal injury and property 

damage if the unit falls.

•  In case of block, brick, concrete or similar type walls, make 5 mm dia. holes 

in the wall.

•  Insert clip anchors for appropriate mounting screws 

6

.

 

NOTE

•  Secure four corners and lower parts of the installation plate with 4 to 6 

mounting screws to install it.

CAUTION

Installation plate
(Keep horizontal direction.)

5 mm dia. hole

Clip anchor
(local parts)

Mounting screw
Ø4 mm x 25

R

 

Anchor bolt

Projection
15 mm or less

m from the right side edge is

e center of pipe hole

35

120

180

240

The center of the pipe hole 
is above the arrow.

Pipe hole

Ø65 mm

23 mm

6

1

Hook

Hook

Hook

Pipe hole

Pipe hole

Installation plate

Mounting 
screw

Weight

Indoor unit

Thread

Anchor bolt holes

50

40

170

132

23

Ø65 mm

300

85

Piping and Drain Hose Installation

*  Since dewing results in a machine trouble, make sure to insulate both 

connecting pipes. (Use polyethylene foam as insulating material.)

     

Piping and drain hose forming

1.  Die-cutting front panel slit

  Cut out the slit on the left or right side of the front panel for the left or right 

connection and the slit on the bottom left or right side of the front panel 
for the bottom left or right connection with a pair of nippers.

Rear right

Rear left

Bottom left

Left

Bottom right

Right

Die-cutting

front panel slit

Changing

drain hose

Piping preparation

2.  Changing drain hose

  For leftward connection, bottom-leftward connection and rearleftward 

connection’s piping, it is necessary to change the drain hose and drain 
cap.

Содержание RAS-18J2AVRG-E

Страница 1: ...AIR CONDITIONER SPLIT TYPE INSTALLATION MANUAL Indoor unit RAS 18J2KVRG E RAS B22J2KVRG E RAS B24J2KVRG E Outdoor unit RAS 18J2AVRG E RAS 22J2AVRG E RAS 24J2AVRG E R32 or R410A 1120650169 ...

Страница 2: ...e 9 OUTDOOR UNIT 9 Installation Place 9 Precautions about Installation in Regions with Snowfall and Cold Temperatures 9 Draining the Water 10 Refrigerant Piping Connection 10 Evacuating 11 ELECTRICAL WORKS 12 Wiring Connection 12 In Case of Indoor Unit Connect With 1 1 Outdoor Unit 13 In Case of Indoor Unit Connect With Inverter Multi System IMS 15 OTHERS 16 Gas Leak Test 16 Remote Control A B Sel...

Страница 3: ...s not require admission or repeated hospital treatment 2 Property damage means greater damage which affects assets or resources For general public use Power supply cord and connecting cable of appliance use shall be at least polychloroprene sheathed flexible cord design H07RN F or cord designation 60245 IEC66 Shall be installed in accordance with national wiring regulations This appliance must be ...

Страница 4: ...Y ELECTRIC PARTS MAY BE DAMAGED CHECK THE EARTH WIRE THAT IT IS NOT BROKEN OR DISCONNECTED BEFORE INSTALLATION DO NOT INSTALL NEAR CONCENTRATIONS OF COMBUSTIBLE GAS OR GAS VAPORS FAILURE TO FOLLOW THIS INSTRUCTION CAN RESULT IN FIRE OR EXPLOSION TO PREVENT OVERHEATING THE INDOOR UNIT AND CAUSING A FIRE HAZARD PLACE THE UNIT WELL AWAY MORE THAN 2 M FROM HEAT SOURCES SUCH AS RADIATORS HEATERS FURNAC...

Страница 5: ...erants may not contain an odour Do not pierce or burn as the appliance is pressurized Do not expose the appliance to heat flame sparks or other sources or ignition Else it may explode and cause injury or death A special tool for the R32 or R410A refrigerant is required for installation Thickness of copper pipes used R32 must be more than 0 8 mm Never use copper pipes thinner than 0 8 mm After comp...

Страница 6: ...ter or other moisture before installation could result in electric shock Do not store it in a wet basement or expose to rain or water After unpacking the unit examine it carefully for possible damage Do not install the unit at place where leakage of flammable gas may occur In case gas leaks and accumulates at surrounding of the unit it may cause of fire Do not install in a place that can increase ...

Страница 7: ...s the filter 1 Recommend to use vacuum to clean by sucking the dusts which stick or dip inside the filter or use the blower to blow the dust go out through the filter 2 If necessary to use water to clean simply use the plain water to wash the filter dry with the sunlight for 3 4 hours or until it completely dry Nevertheless use hair drier to dry it However washing with water it may reduce the perf...

Страница 8: ...parately with insulation not together 8 mm thick heat resisting polyethylene foam 1 Batteries 7 Flat head wood screw 4 Remote control holder Vinyl tape Apply after carrying out a drainage test Wireless remote control Saddle Extension drain hose Not available provided by installer Shield pipe Attach to the front panel Air filter Hook Installation plate Hook 50 mm or more 300 mm or more 170 mm or mo...

Страница 9: ...no obstacles near the air inlet and outlet A place which allows easy installation of the piping to the outdoor unit A place which allows the front panel to be opened The indoor unit shall be installed at least 2 5 m height Also it must be avoided to put anything on the top of the indoor unit CAUTION 5 4 45 5 7 Side view Top view Indoor unit R e c e p t i o n r a n g e Remote control Remote control...

Страница 10: ...fter scribing slits of the front panel with a knife or a making off pin cut them with a pair of nippers or an equivalent tool Slit Slit CAUTION Bind the auxiliary pipes two and connecting cable with facing tape tightly In case of leftward piping and rear leftward piping bind the auxiliary pipes two only with facing tape Indoor unit Connecting cable Auxiliary pipes Installation plate Carefully arra...

Страница 11: ...ll the unit such as to avoid admission of wind 4 Installation in the following places may result in trouble Do not install the unit in such places A place full of machine oil A saline place such as the coast A place full of sulfide gas A place where high frequency waves are likely to be generated as from audio equipment welders and medical equipment Strong wind Do not use the supplied drain nipple...

Страница 12: ...nserted properly if their outer circumferences lift up or the caps catch on or wedge against something Water proof rubber caps supplied with the outdoor unit Base plate Drain nipple 2 Install the drain nipple and a commercially available drain hose with 16 mm inside diameter and drain off the water For the position where the drain nipple is installed refer to the installation diagram of the indoor...

Страница 13: ...2 kgf m H17 14 18 N m 1 4 to 1 8 kgf m A H Hexagon wrench is required Service Port Cap Valve Rod Cap Evacuating After the piping has been connected to the indoor unit you can perform the air purge together at once AIR PURGE Evacuate the air in the connecting pipes and in the indoor unit using a vacuum pump Do not use the refrigerant in the outdoor unit For details see the manual of the vacuum pump...

Страница 14: ...er rear plate bushing and air inlet grille on the indoor unit Cord clamp Terminal cover Screw Screws Air inlet grille Front panel 1 Remove the valve cover the electric parts cover and the cord clamp from the outdoor unit 2 Connect the connecting cable to the terminal as identified by the matching numbers on the terminal block of indoor and outdoor unit 3 Insert the power cord and the connecting ca...

Страница 15: ...al block 3 50 mm 10 mm 70 mm 10 mm Connecting cable Connecting cable connect to 1 2 3 Terminal block L N 1 2 3 Earth line Power supply cable Connecting cable Earth line Earth line Stripping length of the connecting cable Power Supply Input at Outdoor Unit Terminal Block Optional Indoor Unit Outdoor Unit Connecting cable connect to L 2 3 Terminal block L N 1 2 3 Earth line Connecting cable Connecti...

Страница 16: ...ncorrect or incomplete wiring is carried out it will cause an ignition or smoke 9 This product can be connected to main power supply Connection to fixed wiring A switch which disconnects all poles and has a contact separation at least 3 mm must be incorporated in the fixed wiring Power supply input Wiring Diagram for 1 1 Outdoor Unit Indoor Terminal Block Indoor Terminal Block Power supply input P...

Страница 17: ...connected to main power supply Connection to fixed wiring A switch which disconnects all poles and has a contact separation at least 3 mm must be incorporated in the fixed wiring Power supply input Wiring Diagram for Inverter Multi System IMS Indoor Terminal Block Power input Outdoor Terminal Block Chassis Chassis Power input at Outdoor Terminal Block In Case of Indoor Unit Connect With Inverter M...

Страница 18: ...he remote control signal simultaneously and operate In this case the operation can be preserved by setting either one remote control to B setting Both are set to A setting in factory shipment The remote control signal is not received when the settings of indoor unit and remote control are different There is no relation between A setting B setting and A room B room when connecting the piping and ca...

Страница 19: ...e quantity of residue shiny metal dust or other wear residue or mixture of foreign matter is observed trouble will occur 8 When temporary installation and removal of the air conditioner are repeated such as when leased etc 9 If the type of refrigerator oil of the existing air conditioner is other than the following oil Mineral oil Suniso Freol S MS Synthetic oil alkyl benzene HAB Barrel freeze est...

Страница 20: ...1120650169 ...

Отзывы: