Drain
guide

Space for pipes

Wall

Shield pipe

Inside the room

Drain hose

Extension drain hose

Arrange the drain pipe for proper drainage from the unit.
Improper drainage can result in dew-dropping.

This air conditioner has the structure designed 
to drain water collected from dew, which forms 
on the back of the indoor unit, to the drain pan. 
Therefore, do not store the power cord and other 
parts at a height above the drain guide.

CAUTION

OUTDOOR UNIT

OUTDOOR UNIT

Installation Place

•  A place which provides the spaces around the outdoor unit as shown in the 

diagram

•  A place which can bear the weight of the outdoor unit and does not allow an 

increase in noise level and vibration

•  A place where the operation noise and discharged air do not disturb your 

neighbors

•  A place which is not exposed to a strong wind
•  A place free of a leakage of combustible gases
•  A place which does not block a passage
•  When the outdoor unit is to be installed in an elevated position, be sure to 

secure its feet.

•  The allowable length of the connecting pipe.

Model

RAS-18J2AVRG-E RAS-22J2AVRG-E RAS-24J2AVRG-E

Chargeless

up to 15 m

up to 15 m

up to 15 m

Maximum length

20 m

20 m

25 m

Additional 
refrigerant charging

16 - 20 m

(20 g / 1 m)

16 - 20 m

(20 g / 1 m)

16 - 25 m

(20 g / 1 m)

•  The allowable height of outdoor unit installation site.

Model

RAS-18J2AVRG-E RAS-22J2AVRG-E RAS-24J2AVRG-E

Maximum length

12 m

12 m

15 m

•  A place where the drain water does not raise any problems

CAUTION

1.  Install the outdoor unit without anything blocking the air discharging.
2.  When the outdoor unit is installed in a place always exposed to strong 

wind like a coast or on a high storey of a building, secure the normal fan 
operation using a duct or a windshield.

3.  In particularly windy areas, install the unit such as to avoid admission of 

wind.

4.  Installation in the following places may result in trouble.
  Do not install the unit in such places.
  •  A place full of machine oil
  •  A saline-place such as the coast
  •  A place full of sul

fi

 de gas

  •  A place where high-frequency 

waves are likely to be generated 
as from audio equipment, welders, 
and medical equipment

Strong 

wind

•  Do not use the supplied drain nipple for draining water. Drain the water 

from all the drain holes directly.

•  To protect the outdoor unit from snow accumulation, install a holding 

frame, and attach a snow protection hood and plate.

*  Do not use a double-stacked design.

Precautions about Installation in Regions

with Snowfall and Cold Temperatures

Snow protection plate

Snow protection hood

Snow accumulation line

Holding frame

At least
50 cm

Install at least 50 cm
above the snow
accumulation line.

Anchor
bolts

Front

2.  Put water in the drain pan and make sure that the water is drained out of 

doors.

3.  When connecting extension drain hose, insulate the connecting part of 

extension drain hose with shield pipe.

Do not form the
drain hose into
a wavy shape.

Do not rise the
drain hose.

50 mm
or more

Do not put the
drain hose end
into water.

Do not put the
drain hose end
in the drainage ditch.

Drainage

1.  Run the drain hose sloped downwards.

 

NOTE

•  The hole should be made at a slight downward slant on the outdoor side.

When the outdoor unit is installed in a place where the drain water might 
cause any problems, Seal the water leakage point tightly using a silicone 
adhesive or caulking compound.

CAUTION

Precautions for adding refrigerant

 

y

Use a scale having a precision with at least 10 g per index line when 
adding the refrigerant.
Do not use a bathroom scale or similar instrument.

 

y

Use liquid refrigerant when re

fi

lling the refrigerant.

Since the refrigerant is in liquid form, it can 

fi

ll quickly.

Therefore, perform the 

fi

lling operation carefully and insert the refrigerant 

gradually.

Содержание RAS-18J2AVRG-E

Страница 1: ...AIR CONDITIONER SPLIT TYPE INSTALLATION MANUAL Indoor unit RAS 18J2KVRG E RAS B22J2KVRG E RAS B24J2KVRG E Outdoor unit RAS 18J2AVRG E RAS 22J2AVRG E RAS 24J2AVRG E R32 or R410A 1120650169 ...

Страница 2: ...e 9 OUTDOOR UNIT 9 Installation Place 9 Precautions about Installation in Regions with Snowfall and Cold Temperatures 9 Draining the Water 10 Refrigerant Piping Connection 10 Evacuating 11 ELECTRICAL WORKS 12 Wiring Connection 12 In Case of Indoor Unit Connect With 1 1 Outdoor Unit 13 In Case of Indoor Unit Connect With Inverter Multi System IMS 15 OTHERS 16 Gas Leak Test 16 Remote Control A B Sel...

Страница 3: ...s not require admission or repeated hospital treatment 2 Property damage means greater damage which affects assets or resources For general public use Power supply cord and connecting cable of appliance use shall be at least polychloroprene sheathed flexible cord design H07RN F or cord designation 60245 IEC66 Shall be installed in accordance with national wiring regulations This appliance must be ...

Страница 4: ...Y ELECTRIC PARTS MAY BE DAMAGED CHECK THE EARTH WIRE THAT IT IS NOT BROKEN OR DISCONNECTED BEFORE INSTALLATION DO NOT INSTALL NEAR CONCENTRATIONS OF COMBUSTIBLE GAS OR GAS VAPORS FAILURE TO FOLLOW THIS INSTRUCTION CAN RESULT IN FIRE OR EXPLOSION TO PREVENT OVERHEATING THE INDOOR UNIT AND CAUSING A FIRE HAZARD PLACE THE UNIT WELL AWAY MORE THAN 2 M FROM HEAT SOURCES SUCH AS RADIATORS HEATERS FURNAC...

Страница 5: ...erants may not contain an odour Do not pierce or burn as the appliance is pressurized Do not expose the appliance to heat flame sparks or other sources or ignition Else it may explode and cause injury or death A special tool for the R32 or R410A refrigerant is required for installation Thickness of copper pipes used R32 must be more than 0 8 mm Never use copper pipes thinner than 0 8 mm After comp...

Страница 6: ...ter or other moisture before installation could result in electric shock Do not store it in a wet basement or expose to rain or water After unpacking the unit examine it carefully for possible damage Do not install the unit at place where leakage of flammable gas may occur In case gas leaks and accumulates at surrounding of the unit it may cause of fire Do not install in a place that can increase ...

Страница 7: ...s the filter 1 Recommend to use vacuum to clean by sucking the dusts which stick or dip inside the filter or use the blower to blow the dust go out through the filter 2 If necessary to use water to clean simply use the plain water to wash the filter dry with the sunlight for 3 4 hours or until it completely dry Nevertheless use hair drier to dry it However washing with water it may reduce the perf...

Страница 8: ...parately with insulation not together 8 mm thick heat resisting polyethylene foam 1 Batteries 7 Flat head wood screw 4 Remote control holder Vinyl tape Apply after carrying out a drainage test Wireless remote control Saddle Extension drain hose Not available provided by installer Shield pipe Attach to the front panel Air filter Hook Installation plate Hook 50 mm or more 300 mm or more 170 mm or mo...

Страница 9: ...no obstacles near the air inlet and outlet A place which allows easy installation of the piping to the outdoor unit A place which allows the front panel to be opened The indoor unit shall be installed at least 2 5 m height Also it must be avoided to put anything on the top of the indoor unit CAUTION 5 4 45 5 7 Side view Top view Indoor unit R e c e p t i o n r a n g e Remote control Remote control...

Страница 10: ...fter scribing slits of the front panel with a knife or a making off pin cut them with a pair of nippers or an equivalent tool Slit Slit CAUTION Bind the auxiliary pipes two and connecting cable with facing tape tightly In case of leftward piping and rear leftward piping bind the auxiliary pipes two only with facing tape Indoor unit Connecting cable Auxiliary pipes Installation plate Carefully arra...

Страница 11: ...ll the unit such as to avoid admission of wind 4 Installation in the following places may result in trouble Do not install the unit in such places A place full of machine oil A saline place such as the coast A place full of sulfide gas A place where high frequency waves are likely to be generated as from audio equipment welders and medical equipment Strong wind Do not use the supplied drain nipple...

Страница 12: ...nserted properly if their outer circumferences lift up or the caps catch on or wedge against something Water proof rubber caps supplied with the outdoor unit Base plate Drain nipple 2 Install the drain nipple and a commercially available drain hose with 16 mm inside diameter and drain off the water For the position where the drain nipple is installed refer to the installation diagram of the indoor...

Страница 13: ...2 kgf m H17 14 18 N m 1 4 to 1 8 kgf m A H Hexagon wrench is required Service Port Cap Valve Rod Cap Evacuating After the piping has been connected to the indoor unit you can perform the air purge together at once AIR PURGE Evacuate the air in the connecting pipes and in the indoor unit using a vacuum pump Do not use the refrigerant in the outdoor unit For details see the manual of the vacuum pump...

Страница 14: ...er rear plate bushing and air inlet grille on the indoor unit Cord clamp Terminal cover Screw Screws Air inlet grille Front panel 1 Remove the valve cover the electric parts cover and the cord clamp from the outdoor unit 2 Connect the connecting cable to the terminal as identified by the matching numbers on the terminal block of indoor and outdoor unit 3 Insert the power cord and the connecting ca...

Страница 15: ...al block 3 50 mm 10 mm 70 mm 10 mm Connecting cable Connecting cable connect to 1 2 3 Terminal block L N 1 2 3 Earth line Power supply cable Connecting cable Earth line Earth line Stripping length of the connecting cable Power Supply Input at Outdoor Unit Terminal Block Optional Indoor Unit Outdoor Unit Connecting cable connect to L 2 3 Terminal block L N 1 2 3 Earth line Connecting cable Connecti...

Страница 16: ...ncorrect or incomplete wiring is carried out it will cause an ignition or smoke 9 This product can be connected to main power supply Connection to fixed wiring A switch which disconnects all poles and has a contact separation at least 3 mm must be incorporated in the fixed wiring Power supply input Wiring Diagram for 1 1 Outdoor Unit Indoor Terminal Block Indoor Terminal Block Power supply input P...

Страница 17: ...connected to main power supply Connection to fixed wiring A switch which disconnects all poles and has a contact separation at least 3 mm must be incorporated in the fixed wiring Power supply input Wiring Diagram for Inverter Multi System IMS Indoor Terminal Block Power input Outdoor Terminal Block Chassis Chassis Power input at Outdoor Terminal Block In Case of Indoor Unit Connect With Inverter M...

Страница 18: ...he remote control signal simultaneously and operate In this case the operation can be preserved by setting either one remote control to B setting Both are set to A setting in factory shipment The remote control signal is not received when the settings of indoor unit and remote control are different There is no relation between A setting B setting and A room B room when connecting the piping and ca...

Страница 19: ...e quantity of residue shiny metal dust or other wear residue or mixture of foreign matter is observed trouble will occur 8 When temporary installation and removal of the air conditioner are repeated such as when leased etc 9 If the type of refrigerator oil of the existing air conditioner is other than the following oil Mineral oil Suniso Freol S MS Synthetic oil alkyl benzene HAB Barrel freeze est...

Страница 20: ...1120650169 ...

Отзывы: