EN
ES
FR
INDOOR UNIT DISPLAY
1
Hi POWER (Green)
2
FILTER (Orange)
3
PRE. DEF (Preheat/Defrost)
(Orange)
4
TIMER (Yellow)
5
OPERATION (Green)
6
RESET button
2
1
Press
FIX
: Move the louver to the
desired vertical direction.
2
Press
SWING
: To continuously swing
the louver automatically and press
again to stop.
3
For horizontal direction, adjust
manually.
AIR FLOW DIRECTION
5
Note:
• Do not move the louver manually for anything else other than 3 above.
• The louver may automatically position for some operation modes.
Note:
If using the optional wired remote controller, refer to its instructions.
Do not install batteries for hard-wire installation.
ONE-TOUCH
AUTOMATIC OPERATION
8
To automatically select cooling, heating, or fan only operation
1.
Press
MODE
: Select A.
2.
Press
TEMP
: Set the desired temperature.
7
Press the “ONE-TOUCH” button for fully automated operation that is
customized to the typical consumer preferences in your region of the world.
The customized settings: control temperature, air
fl
ow strength, air
fl
ow
direction and others provide comfort with “ONE-TOUCH” of the button. If you
prefer other settings you can select from the many other operating functions
offered.
Press
ONE-TOUCH
: Start the operation.
REMOTE CONTROL
6
PREPARATION BEFORE USE
3
Preparing Filters
1. Open the air inlet grille and remove the air
fi
lters.
2.
Attach
the
fi
lters. (see details in the accessory sheet).
Loading Batteries
1. Remove the battery cover.
2. Insert 2 new batteries (AAA type)
following the (+) and (–) positions.
Clock Setup
1.
Push
CLOCK
●
with the tip of a pencil.
If timer indication is
fl
ashing, go to the next step.
2.
Press
ON
or
OFF
: adjust the time.
3.
Press
SET
: Set the time.
Temperature Unit °F-°C Selection
1. Push and hold CHK
●
button on the Remote
Control with the tip of a pencil, “00” will be
shown on the display.
2.
Press
SLEEP
while pushing CHK
●
.
Note:
1. Repeat above step to reset Remote
Control to °F.
2. Operation mode and temperature
set will reset to initial settings after
changing the temperature unit.
3. Default setting of Remote Control
from factory is °F.
A
C
L
PRESET
ONE-TOUCH
QUIET
SWING
TIMER
ON
FILTER
CHK
˚C/˚F
CLOCK
OFF
CLR
SLEEP
SET
FIX
Hi-POWER ECO
COMFORT
SLEEP
MODE
TEMP
FAN
1
Infrared signal emitter
2
Start/Stop button
3
Mode select button (MODE)
4
Temperature button (TEMP)
5
Fan speed button (FAN)
6
Swing louver button
(SWING)
7
Set louver button (FIX)
8
On timer button (ON)
9
Off timer button (OFF)
!
Sleep timer button (SLEEP)
"
Setup button (SET)
#
Clear button (CLR)
$
Memory and Preset button
(PRESET)
%
One-Touch button
(ONE-TOUCH)
&
High power button
(Hi-POWER)
(
Economy button (ECO)
)
Quiet button (QUIET)
~
Comfort sleep button
(COMFORT SLEEP)
+
Filter reset button (FILTER)
,
Clock Reset button (CLOCK)
-
Check button (CHK)
REMOTE CONTROL A-B SELECTION
4
In case of two systems operating nearby, follow the instructions below to set
the remote control to operate with one indoor unit at a time.
Remote Control B Setup.
1. Press RESET button on the indoor unit to turn the air conditioner ON.
2. Point the remote control at the indoor unit.
3. Push and hold CHK
●
button on the Remote Control with the tip of a
pencil. “00” will be shown on the display.
4.
Press
MODE
while pushing CHK
●
. “B” will show on the display and “00”
will disappear and the air conditioner will turn OFF. B is now memorized.
Note:
1. Repeat above step to reset Remote Control back to A.
2. Remote Control does not display “A”.
3. Default setting of Remote Control from
factory is A.
SYSTEM CHARACTERISTICS
1
1. Three-minute time delay: To protect against frequent compressor starts.
2. Preheating operation: Warm up the unit for several minutes before
providing warm air.
3. Warm air control: When the room temperature reaches the set
temperature, the fan speed is automatically reduced and the outdoor unit
will stop.
4. Automatic defrosting: Fans will stop during defrost operation.
5. Heating capacity: Heat is absorbed from outdoor and released into
the room. When the outdoor temperature is too low, use another
recommended heating apparatus in combination with the air conditioner.
6. Some minor cracking sound may occur when unit operating. This is
normal and is caused by expansion/contraction of plastic.
Note:
Items 2 to 5 for Heating mode
Air conditioner operating conditions
Temp.
Operation
Outdoor Temperature
Room Temperature
Heating
-4°F ~ 75°F (-20°C ~ 24°C)
Less than 82°F (28°C)
Cooling
0°F ~ 115°F (-18°C ~ 46°C)
70°F ~ 90°F (21°C ~ 32°C)
Dry
0°F ~ 115°F (-18°C ~ 46°C)
62°F ~ 90°F (17°C ~ 32°C)
CLR
SLEEP
SET
“B” Display
“00” Display
1110655115-1_EN.indd 3
1110655115-1_EN.indd 3
18/11/56 10:01
18/11/56 10:01
Downloaded from