8-3. Temporary Operation
•
Temporary Auto operation, existence of Auto
Restart, and Temporary Cooling operation can be
set by the TEMPORARY button of the indoor
controller.
Fig. 8-3-1
Table 8-3-1
8-3-1. Temporary auto operation
•
When the TEMPORARY button is pushed, the
Auto operation with set temperature fixed at 25
°
C
starts. Controlling is same as that of Auto opera-
tion by the remote controller.
•
When the TEMPORARY button is pushed again,
the operation stops.
•
During Temporary Auto operation, operation by the
remote controller is accepted.
•
Using the Auto Restart function, the Temporary
Auto operation starts when power failure is reset.
8-3-2. Temporary cooling operation
•
When the TEMPORARY operation button keeps
pushed for 10 seconds, Cooling operation of
which compressor motor speed and the indoor fan
speed are fixed starts.
Compressor motor speed :
13 : 30 rps
Indoor fan speed : Low
•
When the TEMPORARY operation button is
pushed again, the operation stops.
•
Auto Restart function is unavailable.
TEMPORARY button
TEMPORARY button
TEMPORARY button
OFF
→
ON
After pushing button
for 3 seconds
After pushing button
for 10 seconds
Control
Temporary Auto operation start
Auto Restart
control select
Temporary Cooling
operation start