– 17 –
FILE NO. SVM-03008
5. SPECIFICATION OF ELECTRICAL PARTS
5-1. Indoor Unit
No.
Parts name
Type
Specifications
1
Fan motor (for indoor)
ICF-340-30-2
DC 340 V, 30 W
2
Thermo. sensor (TA-sensor)
———
10 k
Ω
at 25
°
C
3
DC-DC transformer (T01)
SWT-70
DC 390 V, Secondary DC 15 V, 12 V, 7 V
4
Microcomputer
µ
PD780024AGK
5
Heat exchanger sensor
———
10 k
Ω
at 25
°
C
(TC-sensor)
6
Line filter (L01
SS11V-06270
27mH, AC 0.6A
7
Diode (DB01)
D3SBA60
4A, 600 V
8
Capacitor (C03)
KMH450VNSN120M25C
120
µ
F, 450 V
9
Fuse (F01)
FCU250V, 3.15A
T3.15A, 250 V
10
Power supply IC (IC01)
STR-L472
11
Varistor (R21, R109)
15G561K
560 V
12
Resistor (R01)
RF-5TK4R7
4.7
Ω
, 5 W
13
Louver motor
MP24GA
Output (Rated) 1 W,16 poles, 1 phase,
DC 12 V
5-2. Outdoor Unit
No.
Parts name
Model name
Rating
1
SC coil
L01
ADR2516-0R6TB
20A, 150
µ
H
(Noise filter)
L03
ADR2520-R15TB
15A, 0.6mH
Primary side DC280V, Secondary
2
DC-DC transformer
SWT-43
side 7.5 V x 1, 13 V x 1, 26.5V x 3,
16 V x 1, 15 V x 1
3
Reactor
CH-57-Z-T
L=10mH, 16A x 2
4
Outside fan motor
ICF-140-43-1
DC140 V, 43 W
5
Suction temp. sensor
(Inverter attached)
10 k
Ω
(25
°
C)
(TS sensor)
6
Discharge temp. sensor
(Inverter attached)
62 k
Ω
(20
°
C)
(TD sensor)
7
Outside air temp. sensor
(Inverter attached)
10 k
Ω
(25
°
C)
(TO sensor)
8
Heat exchanger temp.
(Inverter attached)
10 k
Ω
(25
°
C)
sensor (TE sensor)
9
Terminal block (6P)
———
20A, AC 250 V
10
Fuse
For protection of switching power source
3.15A, AC 250 V
For protection of inverter input overcurrent
25A, AC 250 V
11
Electrolytic capacitor
LLQ2G501KHUATF, 400LISN500K35F
500
µ
F, DC 400 V x 3 pieces
12
Transistor module
6MBI25GS-060-01 or 6MBI25GS-060-01A
25A, 600 V
13
Compressor
DA91A1F-45F
3-phases 4-poles 750 W
14
Compressor thermo.
PW-2AL
OFF: 125 ± 4
°
C, ON: 90 ± 5
°
C
15
Converter module
MP7003
Diode: 25A, 600 V,
IGBT: 40 A, 600V