33
−
FILE NO. SVM-09030
3
1
2
Air inlet grille
Front panel
Earth line
Terminal
block
Cord clamp
Screw
Screw
Screw
Power cord
connect cover
Power supply cord
Stripping length of the power supply cord
N
L
40 mm
10 mm
30 mm
10 mm
Earth line
NOTE
•
Use stranded wire only.
•
Wire type : H07RN-F or more
•
For the air conditioner with the power supply cord
If the power supply cord is damaged, it must be
replaced by the manufacturer, the service
agency, or another similarty qualitied
person in order to avoid hazard.
CAUTION
Put the power supply cord
through the notch.
Taking out the power cord
Notch
Wiring Connection
For the air conditioner that does not have power cord,
connect a power cord to it as mentioned below
(1) Open the air inlet grille upward.
(2) Remove the two screws securing the front panel.
(3) Slightly open the lower part of the front panel, then
pull theupper part of the front panel toward you to
remove it from the rear plate.
(4)
After removing the front panel, remove the
power cord connect cover and the cord clamp.
(5) Connect and secure the power supply cord and
secure the cord clamp and the power cord
(6) Put the power supply cord through the notch.
(7) Be sure to smooth the notch with a
How to connect the power cord
connect cover.
Fig. 8-4-5
Fig. 8-4-6