– 64 –
1) Stop the operation of air-conditioner, and
disconnect the power cord from the AC
supply.
2) Remove packed valve cover and Electric
parts cover.
(
2-Screws
∅
4 x 10L)
3) Remove the cord clamp (2-Screws
∅
4 x 16L)
and disconnect the connecting cable.
4) Remove the upper cabinet (
5-Screws
∅
4 x 10L)
Pulling out upword.
5) Remove the front cabinet.
(3-Screws
∅
4 x 10L)
Pull the front right portion toward you, and
remove it pulling out upward.
1) Perform the common procedure
1
.
2) Remove the fixing screw and the capacitor
band.
(1-Screw
∅
4 x
10L)
3) Disconnect the lead wires.
1) Perform the common procedure
1
.
2) Remove the fixing screw and the capacitor
band.
(1-Screw
∅
4 x 10L)
3) Disconnect the lead wires.
10-2. Outdoor Unit
1
Common
procedure
2
Capacitor for
compressor
3
Capacitor for
fan motor
No.
Part name
Procedures
Remarks
Upper
cabinet
Front
FILE NO. SVM-09030
cabinet
Capacitor
f
or
compressor
Capacitor band
Capacitor
Screws
Ø4 x10L
Screws
∅
4 x 10L
for fan motor
Cord clamp
2-Screws Ø4 x10L
Packed valve cover
2-Screws Ø4 x 16L