13
−
4-6. Outdoor Unit (RAS-10UA-ES3)
No. Parts name Type Specifications
Output (Rated) 750 W, 2 poles, 1 phase, 220
−
240 V, 50Hz
1 Compressor PA108X1T-4FZ1 Winding resistance (
Ω
) C-R C-S
(at 20
°
C) 3.89 4.51
Output (Rated) 20 W, 6 poles, 1 phase, 220
−
240 V, 50Hz
2 Fan motor (for outdoor) HF-240-20B or Winding resistance (
Ω
) Red-Black White-Black
(at 20
°
C)
387.3 or 235.2
466.2 or 260.1
3
Running capacitor
DS451155BPQC AC 450 V, 1.5
µ
F
(for fan motor)
4
Running capacitor
DS371256CPNB AC 370 V, 25
µ
F
(for compressor)
4-5. Outdoor Unit (RAS-13UA-ES3)
No. Parts name Type Specifications
Output (Rated) 1100 W, 2 poles, 1 phase, 220
−
240 V, 50Hz
1 Compressor PA150X2T-4FM1 Winding resistance (
Ω
) C-R C-S
(at 20
°
C) 2.49 3.95
Output (Rated) 30 W, 6 poles, 1 phase, 220
−
240 V, 50Hz
2 Fan motor (for outdoor) HF-240-30B Winding resistance (
Ω
) Red-Black White-Black
(at 20
°
C) 245.0 388.3
3
Running capacitor
DS451155BPQC AC 450 V, 1.5
µ
F
(for fan motor)
4
Running capacitor
DS371306CPNB AC 370 V, 35
µ
F
(for compressor)
FILE NO. SVM-04017
SKF-240-20B