– 4 –
MODEL
RAS-10UKH-ES3 / RAS-10 UAH-ES3 RAS-10UK-ES3 / RAS-10 UA-ES3
ITEM
Cooling
Heating
Cooling
Capacity
220 V
240 V
220 V
240 V
220 V
240 V
kW 2.70
2.70
2.90
2.96
2.70
2.70
Phase 1
∅
Power source V 220
-
240
Hz
50
Power consumption
kW 0.82
0.84
0.78
0.82
0.82
0.84
Power factor
% 98
97
97
96
98
97
Running
Indoor
A
0.15
current Outdoor
A 3.65
3.45
3.50
3.40
3.65
3.45
Starting current A 1
8
1
8
Moisture removal
lit/h
1.2
Noise
Indoor (H/M/L)
dB
39/33/26
Outdoor (220
-
240 V) dB 47 49 47 49 46 47
Refrigerant
Name of refrigerant
R410a
Rated amount kg
0.70
0.65
Refrigerant control
Capillary tube
Gas side size mm
∅
9.52
Connection type
Flare connection
Liquid side size mm
∅
6.35
Interconnection Connection type
Flare connection
pipe
Maximum length
m
10*
1
(One way)
Maximum height
difference
INDOOR UNIT
RAS-10UKH-ES3 RAS-10UK-ES3
Height
mm
275
Dimensions
Width
mm
790
Depth
mm
208
Net weight
kg
10
Evaporator type
Finned tube
Indoor fan type
Cross flow fan
High fan
m
3
/h
570
610
610
Air volume Medium fan
m
3
/h
460
520
460
Low fan
m
3
/h
340
400
340
Fan motor output
W
20
Air filter
Honeycomb woven filter with PP frame
OUTDOOR UNIT
RAS-10UAH-ES3 RAS-10UA-ES3
Height
mm
550
Dimensions
Width
mm
780
Depth
mm
270
Net weight
kg
32
30
Condenser type
Finned tube
Outdoor fan type
Propeller fan
Airflow volume
m
3
/h
2030
2150
2030
2150
1740
1850
Fan motor output
W
30
20
Compressor
Model
PA108X1T-4FZ1
Output
W
750
Safety device Fuse, Overload relay
Louver type
Automatic louver
Usable outdoor temperature range
°
C
15 ~ 43
-
10 ~ 24 15 ~ 43
5
m
FILE NO. SVM-04017