6-1. Indoor Unit
No.
Parts name
Type
Specifications
10,13k
AFN-220-20-4D AC 240V, 20W
16k
ICF-340-30-2B DC 340V, 30W
2 Room temp. sensor (TA-sensor)
( - )
10kW at 25°C
3 Heat exchanger temp. sensor (TC-sensor)
( - )
10kW at 25°C
4 Louver motor 24BYJ48-HT Output (Rated) 1W, 16 poles, DC12V
6-2. Outdoor Unit
No.
Parts name
Type
Specifications
16k
JX0-5B
L = 10mH, 16A
10,13k CH-69 (1 Pc) L = 19mH, 10A
2
Outdoor fan motor
ICF-140-43-4R
DC140V, 43W
3 Suction temp. sensor (TS sensor)
(Inverter attached) 10kW (25°C)
4 Discharge temp. sensor (TD sensor)
(Inverter attached) 62kW (20°C)
5 Outside air temp. sensor (TO sensor)
(Inverter attached) 10kW (25°C)
6 Heat exchanger temp. sensor (TE sensor) (Inverter attached) 10kW (25°C)
20A, AC250V
Reactor
1
1
Fan motor
(for indoor)
Terminal block
7
3-phases 4-poles 1100W
10k
DA89X1C-23FZ2
16k
DA131S1B-31FZ
CAM-MD12TCTH-5
STF
3-phases 4-poles 750W
DC12V
AC220-240V
Coil for 4-way valve
COIL FOR P.M.V.
Compressor
8
9
10
13k
DA108X1C-23FZ
3-phases 4-poles 750W
6. SPECIFICATIONS OF ELECTRICAL PARTS
FILE NO. SVM-13001
– 21 –
CH-57 (2 Pcs)