20
−
FILE NO. SVM-040
01
5-4. RAS-10UKP-ES
3
/ RAS-10UA-ES
3
RAS-10UKP-AS
3
/ RAS-10UA-AS
3
Note :
•
Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
Standard
0.95
11.0
High
27/19
35/24
Cooling Overload
1.15
15.0
High
32/23
43/26
Low temperature
0.85
5.0
Low
21/15
21/15
Fan speed
(indoor)
50Hz
Indoor unit
Cross flow fan
Cooling
Cooling Compressor
Condenser
Propeller fan
Outdoor unit
PA108X1T-4FZ1
Cooling
Mark( )means check points of Gas Leak.
O.D.:9.52mm
O.D.:6.35mm
Cooling
Packed valve
(
∅
9.52)
Packed valve
(
∅
6.35)
0.39m
(Connecting pipe)
∅
9.52
0.49m
(Connecting pipe)
∅
6.35
T1
P
Refrigerant
R410A : 0.65 kg.
Evaporator
Capillary tube
∅
1.5x1100
l
Standard
pressure P
(MPaG)
Surface temp. of heat
exchanger interchanging
pipe T1 (°C)