19
−
FILE NO. SVM-040
01
Heat exchanger
Indoor unit
Cross flow fan
Cooling
Cooling Compressor
Condenser
Propeller fan
Outdoor unit
Capillary tube
∅
1.5x500
PA150X2T-4FM1
Cooling
Mark( )means check points of Gas Leak.
O.D.:12.7mm
O.D.:6.35mm
Cooling
Packed valve
(
∅
12.7)
Packed valve
(
∅
6.35)
0.39m
(Connecting pipe)
∅
12.7
0.49m
(Connecting pipe)
∅
6.35
T1
P
Refrigerant
R410A : 0.9
5
kg.
5-3. RAS-13UKP-ES
3
/ RAS-13UA-ES
3
RAS-13UKP-AS
3
/ RAS-13UA-AS
3
Note :
•
Measure the heat exchanger temperature at the center of U-bend. (By means of TC sensor)
Ambient temp.
conditions DB/WB
(°C)
Indoor
Outdoor
Standard
0.90
9.0
High
27/19
35/24
Cooling Overload 1.
03
13.0 High 32/23 43/26
Low temperature
0.70
2.0
Low
21/15
21/15
Fan speed
(indoor)
50Hz
Standar d
pressure P
(MPaG)
Surface temp. of heat
exchang er inter changing
pipe T1 (°C)
l