4. SPECIFICATION OF ELECTRICAL PARTS
4-1. Indoor Unit (RAS-13UKHP-ES3, RAS-13UKHP-AS3, RAS-10UKHP-ES3,
RAS-10UKHP-AS3)
No.
Parts name
Type
Specifications
1
Fan motor (for indoor)
SKF-220-20-4A-1
mo fuse
2 Thermo sensor (T
3
Switching transformer (T01)
SWT-47
4
Microcontroller unit (IC30)
TMP87CM40AN
5
Heat exchanger sensor
(TC-sensor)
6
Line filter (L01)
LC*SS11V-06270
7
Bridge rectifier (DB01)
D3SBA60
4A, 600V
8
Capacitor (C02)
KMH400VSSN47M22S 47
µ
F, 400V
9
Fuse (F01)
TSCR6.3A
T6.3A, 250VAC
10 Varistor (R21, R22) 15G561K 560V
11 Resistor (R01) RF-2TK5R6 5.6
Ω
, 2W
12 Louver motor MP24
Z
12VDC
13 Relay (Comp., RY01)
DI12D1
Rating 20A/AC250V, 12VDC
14
Relay (Fan, RY03)
G5N-1A
Rating 3A/AC250V, 12VDC
15
Relay (Solenoide, RY04)
G5N-1A
Rating 3A/AC250V, 12VDC
4-2. Outdoor Unit (RAS-13UAH-ES3, RAS-13UAH-AS3)
No.
Parts name
Type
Specifications
Output (Rated) 1100W, 2poles, 1 phase, 220
−
240V, 50Hz
1
Compressor
PA150X2T-4FM1 Winding resistance (
Ω
)
C-R
C-S
(at 20°C)
2.49
3.95
Output (Rated) 42W, 6poles, 1 phase, 220
−
240V, 50Hz
2 Fan motor (for outdoor) HF-240-42
A
Winding resistance (
Ω
) Red-Black White-Black
(at 20°C)
176.2
290.5
3
Running capacitor
DS451155BPQC AC 450V, 1.5
µ
F
(for fan motor)
4
Running capacitor
DS371306CPNB AC 370V, 30
µ
F
(for compressor)
Solenoid coil
5
(for 4-way valve)
VHV-01AJ503C1 AC 220
−
240V, 50Hz
(for Heat pump model)
AC Motor with 150°C ther
A-sensor)
10k
Ω
at 25°C
10k
Ω
at 25°C
27mH, 600mA
Ω
Ω