6F3B0250
214
T1/T1S User’s Manual
7. Instructions
FUN 114
SET
Device/register set
Expression
Input
-
[ SET
A
]
-
Output
Function
When the input is ON, the device
A is set to ON if A is a device, or the data HFFFF is stored in the
register
A if A is a register.
Execution condition
Input
Operation
Output
OFF
No execution
OFF
ON
Execution
ON
Operand
Name
Device
Register
Constant Index
X
Y
R
S
T.
C. XW YW RW SW
T
C
D
I
J
K
A
Device or
register
Ö
Ö
Ö
Ö
Ö
Ö
Ö
Ö
Ö
Ö
Ö
Ö
Example 1 (device set)
When R010 is ON, R025 is set to ON. The state of R025 is remained even if R010 comes OFF.
Example 2 (register set)
When R010 is ON, the data HFFFF is stored in RW20. (R200 to R20F are set to ON)
The state of RW20 is remained even if R010 comes OFF.