background image

 

 Cooling / Heating operations

•  When the outdoor temperature goes out of the operable range, cooling or heating operation may not be 

performed in order to protect the equipment. In this case, “   ” goes on.

•  If the outside temperature decreases during operation, the fan of the outdoor unit may stop.

 

 Characteristics of heating

•  Air does not come out immediately after heating starts. Heated air comes out after 3 to 5 minutes (depending on 

the room/outside temperatures), after the indoor heat exchanger warms up.

•  When the outside temperature increases, the outdoor unit may stop.
•  While an indoor unit is running in the heating mode, the outdoor unit supplies refrigerant to the other indoor units 

which are not running. There, noise may come from the other indoor units or the exterior of them may become 
warm.

•  If the Fan operation is performed while the Heat operation is performed in another room, the fan does not run.

 

 Prohibition of NFC function (NFC tag)

NFC communications is enabled at the time of shipping from the factory, but it is possible to disable the test run with 
a smart phone.
Please consult dealer from where you purchased it for more details.

 

 Caution for indoor units using R32 refrigerant.

•  This unit is equipped with safety measures that use a power supply. After installation, the unit shall always be 

powered on, except during service.

•  When the option product "leak detector" detects the leakage of refrigerant, “J30” is displayed on the remote 

controller, and the fan of the indoor unit is operated to prevent the refrigerant from staying, and even if the 
ON / OFF operation button on the remote controller is pressed. Will not stop. In such a case, ventilate the room 
without turning off the power and contact the store immediately. Also, do not use burning appliances such as 
stoves.

•  Don’t use gas equipments (propane, methane, etc.) that uses 

fl

ammable gas, pesticides, 

fl

ammable gas such as 

hair spray (LPG, etc.), and spray used siloxane, drugs, chemicals, and paints etc. near a leak detector, since it 
may cause false detection of refrigerant leakage.

9

  Tips for energy saving and comfortable 

performance

To save energy and perform comfortable cooling and heating

Clean the air 

fi

lter often

•  A clogged air 

fi

lter lowers the cooling / heating 

performance.

Check 

periodically!

Do not cool / heat too much

 

WARNING

Do not expose your body to cool air directly for a 
long time and do not cool yourself excessively.

Doing so may result in deteriorated physical condition 
and ill health.

•  Cooling / Heating too much is bad for your health.

In particular, take care with handicapped / old people 
and children.

Do not cool 

down too 

much!

Close windows and doors

•  Do not let cooled / heated air escape from the room.

Close.

Cool / Heat the room evenly

•  Adjust the air direction with the louver.

Exposing yourself to blowing air directly for a long 

time is bad for your health.

Air conditioner operating conditions

For proper performance, operate the air conditioner under the following temperature conditions:

Cooling operation

Outdoor temperature

: –15°C to 50°C (Dry-bulb temp.)

Room temperature

[CAUTION]

Room relative humidity: less than 80%. If the air conditioner operates in excess 

of this 

fi

gure, the surface of the air conditioner may cause dewing.

Heating operation

Outdoor temperature

: –25°C to 15.5°C (Wet-bulb temp.)

Room temperature

If air conditioner is used outside of the above conditions, safety protection may operate.

– 14 –

27-EN 

28-EN

Содержание MMY-SUG0801MT8P-E

Страница 1: ...l MMY SUG0801MT8P E MMY SUG1001MT8P E MMY SUG1201MT8P E MMY SUG1401MT8P E MMY SUG1601MT8P E MMY SUG1801MT8P E MMY SUG2001MT8P E MMY SUG2201MT8P E MMY SUG2401MT8P E MMY SUG0801MT8JP E MMY SUG1001MT8JP E MMY SUG1201MT8JP E MMY SUG1401MT8JP E MMY SUG1601MT8JP E MMY SUG1801MT8JP E MMY SUG2001MT8JP E MMY SUG2201MT8JP E MMY SUG2401MT8JP E ...

Страница 2: ...he air conditioners made by Toshiba Carrier Corporation He or she has been trained to install repair maintain relocate and remove the air conditioners made by Toshiba Carrier Corporation or alternatively he or she has been instructed in such operations by an individual or individuals who have been trained and is thus thoroughly acquainted with the knowledge related to these operations The qualifie...

Страница 3: ...ndicates damage extending to buildings household effects domestic livestock and pets Precautions for using R32 refrigerant These safety cautions describe important matters concerning safety to prevent injury to users or other people and damages to property Please read through this manual after understanding the contents below meanings of indications and be sure to follow the description Meanings o...

Страница 4: ...ure that the air conditioner is transported in stable condition If you find any part of the product broken contact your dealer The appliance shall be stored in a room without continuously operating ignition sources for example open flames an operating gas appliance or an operating electric heater Do not pierce or burn Be aware that refrigerants may not contain an odour Installation Only a qualifie...

Страница 5: ... person Do not climb onto or place objects on top of the outdoor unit You may fall or the objects may fall off of the outdoor unit and result in injury Do not place any combustion appliance in a place where it is directly exposed to the wind of air conditioner otherwise it may cause imperfect combustion When the air conditioner is operated with a combustion appliance in the same place be careful o...

Страница 6: ...red that there is a danger of the indoor unit s falling do not approach the indoor unit but set the circuit breaker to the OFF position and contact a qualified installer or a qualified service person to refit the unit Do not set the circuit breaker to the ON position until the unit has been refitted If you have discovered that there is a danger of the outdoor unit s toppling over do not approach t...

Страница 7: ...de the unit Do not put a water container such as a vase on the unit Water intrusion into the unit may occur and it may cause deterioration of electric insulation and result in electric shock Ask for cleaning of the air conditioner to be performed by the dealer Cleaning the air conditioner in an improper manner may cause damage to plastic parts insulation failure of electric parts etc and result in...

Страница 8: ...owner s manuals that come with the indoor units 2 Part names Outdoor unit Air discharge Warm air comes out when cooling and cool air when heating Refrigerant Conduit Connector Connecting valve inside Air intake Provided on the three sides Earth screw Equipped on the electrical control box NFC tag NFC Near Field Communication Power wire hole Indoor unit 4 Way Cassette Type MMU UP H Discharge louver...

Страница 9: ...Type MMU UP YH Air intake grille Air in the room is taken in through here Discharge louver Controls discharge air directions Earth screw Equipped on the electrical control box Air filter Filters out dust Inside the return air grille MMU UP SH Discharge louver Controls discharge air directions Earth screw Equipped on the electrical control box Air intake grille Air in the room is taken in through h...

Страница 10: ...ntroller Remote controller model name RBC ASCU11 E LCD backlight lights for 15 seconds during remote controller operation All indicators are displayed in the display example below Actually only the selected options will be displayed Operations 1 2 3 4 Operation lamp Lights during operations Blinks when a check occurs or the protective device activates 1 ON OFF button Turns on the unit when pushed ...

Страница 11: ...ngs Standby Operations are not accepted when SETTING is blinking REQUIREMENT Keep the power switch turned on during use When you resume using the air conditioner after a long period of disuse turn on the power switch at least 12 hours before starting running When the power is turned on it takes about 1 minute before the remote controller becomes operable This is not a malfunction Running operation...

Страница 12: ...the surface of the air discharge or louver and may drop down NOTE If pointing horizontally for cooling dew may form on the surface of the cabinet or louver and may drop down If pointing horizontally for heating the room temperature may be uneven Do not handle the louver manually Doing so may cause a failure Use the remote controller to adjust the angle To set the louver direction and auto swing 1 ...

Страница 13: ...upward The swing indication appears on the remote controller even in pre heating mode but the actual swing starts only after pre heating is complete Under ceiling type Vertical adjustment T When cooling Point the louver horizontally to send cool air across the entire room T When heating Point the louver downward to send heated air to the floor The louver automatically closes when running is stoppe...

Страница 14: ...ot increase If something is placed near the air discharge of the outdoor unit noise may increase Be careful not to disturb your neighbors with cool warm air or noise coming from the air discharge of the outdoor unit 8 Notes on operations and performance Check before operation Turn on the power switch at least 12 hours before starting operation Make sure the earth wire is securely connected Make su...

Страница 15: ...troller is pressed Will not stop In such a case ventilate the room without turning off the power and contact the store immediately Also do not use burning appliances such as stoves Don t use gas equipments propane methane etc that uses flammable gas pesticides flammable gas such as hair spray LPG etc and spray used siloxane drugs chemicals and paints etc near a leak detector since it may cause fal...

Страница 16: ...or so to dry the inside Turn off the main power switch Clean the air filter and then attach it Turn on the power again In case of R32 refrigerant model Periodic inspection After being used for a long period of time the parts may deteriorate or malfunction or the drainage may worsen due to heat moisture dust or general usage In addition to the maintenance it is recommended that you have a inspectio...

Страница 17: ... remote controller Is outdoor temperature out of operation temperature range Air is not cooled or warmed sufficiently Is the air intake or air discharge of the outdoor unit obstructed Are any door or window open Is the air filter clogged with dust Is discharge louver of the indoor unit set at appropriate position Is air selection set to Low Med and is the operation mode set to Fan Is the setup tem...

Страница 18: ...016 2281 http ecodesign toshiba airconditioning eu en When the Leak Detector buzzer sounds If the sensor detects refrigerant leakage Alarm lamp blinks and buzzer sounds a warning sound Push this button to stop warning sound Even if the buzzer sound is released Alarm lamp will not be released Procedure stopping buzzer The alarm can be stopped by pressing the alarm lamp button for at least 2 seconds...

Страница 19: ...ent 203 Flow Selector unit battery dead The battery kit connected to the Flow Selector unit has reached the end of its life 204 Leak detector life advance display The leak detector will soon reach the end of its life Declaration of Conformity Manufacturer Toshiba Carrier Thailand Co Ltd 144 9 Moo 5 Bangkadi Industrial Park Tivanon Road Tambol Bangkadi Amphur Muang Pathumthani 12000 Thailand TCF ho...

Страница 20: ...MT8P E MMY SUG1401MT8P E MMY SUG1601MT8P E MMY SUG1801MT8P E MMY SUG2001MT8P E MMY SUG2201MT8P E MMY SUG2401MT8P E MMY SUG0801MT8JP E MMY SUG1001MT8JP E MMY SUG1201MT8JP E MMY SUG1401MT8JP E MMY SUG1601MT8JP E MMY SUG1801MT8JP E MMY SUG2001MT8JP E MMY SUG2201MT8JP E MMY SUG2401MT8JP E Commercial name Super Heat Recovery Multi Air Conditioner Complies with the provisions of the Supply of Machinery ...

Страница 21: ...1140102201 ...