18
7
APPLICABLE CONTROLS
NOTIFICATION
When using the equipment for the first time, the remote controller will not accept any commands for a short
period of time.
• Automatic address
• While automatic addressing no operations can be performed on the remote control.
• Automatic addressing will take a maximum duration of 10 minutes (generally 5 minutes).
• Upon turning on the unit after completion of automatic addressing, a maximum period of
10 minutes (generally 3 minutes) are required prior to the start up operation of the outdoor unit.
All indoor units are shipped from factory as standard. Change if necessary.
To change the setup use the main remote controller (wired remote controller).
* The setup change for wireless remote controller, sub remote controller or a unit without a controller (Centrally
controlled.) is not possible. In such cases, temporarily install a separate main remote controller.
Applicable control setup
Basic operation procedure for setup change
Change the setup while operation of the equipment is stopped.
(Be sure to stop the operation of a set.)
ON / OFF
FAN
TEMP.
SWING/FIX
TIME
MODE
VENT
UNIT
SET
CL
FILTER
RESET TEST
TIMER SET
CODE No.
UNIT No.
R.C.
No.
1
2
3
5
6
6
Procedure
1
2
3
4
5
6
Description
Push the
SET
,
CL
and
TEST
buttons simultaneously for 4 seconds or more, after a while, the display part flashes
as shown in the figure.
Check that the displayed item code is [10].
• If the item code indicates any characters other than [10], push the
TEST
button to erase the display and retry the operation from the first step.
(For some time after the
TEST
button has been pushed, the operation
of the remote controller cannot be accepted.)
(In a group control, the firstly displayed
indoor unit No. becomes the center unit.)
Each time the
UNIT
button is pressed, the indoor unit No. in the group control is displayed consecutively.
Select the indoor unit that requires a change to the setup.
During this time the indoor unit that is selected can be
confirmed as the louver and fan will be operated.
Using
TEMP.
the buttons, select the item code [
**
].
Using the
TIME
buttons, select set data [
****
].
Push the
SET
button. During this time, if the display changes from flashing to permanently on, the setup is
complete.
• To change the setup of an indoor unit that is not selected, restart operation from Procedure
2
.
• To change to a different setup within the selected indoor unit, restart operation from Procedure
3
.
Pushing the
CL
button clears the set up contents which has been set. In this case, restart from Procedure
2
.
When the setup is finished, push the
TEST
button. (The setup is configured.)
Pushing the
TEST
button deletes the display and returns the status to the
normal stopped status.
(For a period of time after the
TEST
button has been pushed, the remote
controller will not accept any commands.)
(* The display changes according
to the indoor unit model.)
CODE No.
UNIT No.
R.C.
No.
∗∗ ∗
∗∗
∗
∗
∗
∗ ∗∗
CODE No.
UNIT No.
SETTING
R.C.
No.