![Toshiba M200 - Portege - Pentium M 1.5 GHz Скачать руководство пользователя страница 154](http://html.mh-extra.com/html/toshiba/m200-portege-pentium-m-1-5-ghz/m200-portege-pentium-m-1-5-ghz_maintenance-manual_424838154.webp)
3
Tests and Diagnostics
3.20
HDC
Status
3-52
Portege M200 Maintenance Manual (960-457)
3.20 HDC Status
When an error occurs in the hard disk test, the following message is displayed:
HDC status = XXXX
The hard disk test error status is displayed on the screen by a four-digit number.
The hard disk controller error status is composed of two bytes; the first byte displays the contents
of the HDC error status register and the second byte displays the HDC error register. Each of them
are indicated in hexadecimal form
The contents of the HDC error status register and error register are listed in Tables 3-5 and 3-6.
Table 3-5 Hard disk controller status register contents
Bit
Name
Description
7
BSY
(Busy)
“0” … HDC is ready.
“1” … HDC is busy.
6
DRDY
(Drive ready)
“0” … Hard disk drive is not ready to accept any command.
“1” … Hard disk drive is ready.
5
DWF
(Drive write fault)
“0” … DWF error is not detected.
“1” … Write fault condition occurred.
4
DSC
(Drive seek complete)
“0” … The hard disk drive heads are not settled over a track.
“1” … The hard disk drive heads are settled over a track.
3
DRQ
(Data request)
“0” … Drive is not ready for data transfer.
“1” … Drive is ready for data transfer.
2
CORR
(Corrected data)
“0” … Not used
“1” … Correctable data error is corrected.
1
IDX
(Index)
“0” … Not used
“1” … Index is sensed.
0
ERR
(Error)
“0” … Not used
“1” … The previous command was terminated with an error.
Содержание M200 - Portege - Pentium M 1.5 GHz
Страница 1: ...1 Toshiba Personal Computer Portege M200 Maintenance Manual TOSHIBA CORPORATION File Number 960 457 ...
Страница 9: ...Portege M200 Maintenance Manual 960 457 ix Appendix H Key FD H 1 ...
Страница 10: ...x Portege M200Maintenance Manual 960 457 ...
Страница 11: ...Chapter 1 Hardware Overview ...
Страница 12: ...1 Hardware Overview 1 ii Portege M200 Maintenance Manual 960 457 1 Hardware Overview ...
Страница 33: ...Chapter 2 Troubleshooting Procedures ...
Страница 34: ...2 Troubleshooting Procedures 2 ii Portege M200 Maintenance Manual 960 457 2 ...
Страница 38: ...2 Troubleshooting Procedures 2 vi Portege M200 Maintenance Manual 960 457 ...
Страница 96: ...2 Troubleshooting Procedures 2 16 Bluetooth Troubleshooting 2 58 Portege M200 Maintenance Manual 960 457 ...
Страница 97: ...Chapter 3 Tests and Diagnostics ...
Страница 98: ...3 Tests and Diagnostics 3 ii Portege M200 Maintenance Manual 960 457 3 ...
Страница 119: ...3 7 Keyboard Test 3 Tests and Diagnostics Portege M200 Maintenance Manual 960 457 3 19 PRESS Enter KEY ...
Страница 184: ...Chapter 4 Replacement Procedures ...
Страница 185: ...4 Replacement Procedures 4 ii Portege M200 Maintenance Manual 960 457 4 ...
Страница 189: ...4 Replacement Procedures 4 vi Portege M200 Maintenance Manual 960 457 ...
Страница 258: ...Appendices ...
Страница 259: ...Appendices App ii Portege M200 Maintenance Manual 960 457 ...
Страница 265: ...Appendices App viii Portege M200 Maintenance Manual 960 457 ...
Страница 271: ...Appendices Apx A Handling the LCD Module A 6 Portege M200 Maintenance Manual 960 457 ...
Страница 279: ...Appendices Apx B Board Layout B 8 Portege M200 Maintenance Manual 960 457 ...
Страница 309: ...Appendices Apx C Pin Assignment C 30 Portege M200 Maintenance Manual 960 457 ...
Страница 319: ...Appendices Apx E Key Layout E 2 Portege M200 Maintenance Manual 960 457 ...
Страница 321: ...Appendices Apx F BIOS KBC EC Update F 2 Portege M200 Maintenance Manual 960 457 ...
Страница 323: ...Appendices Apx G Reliability G 2 Portege M200 Maintenance Manual 960 457 ...
Страница 325: ...Appendices Apx H Key FD H 2 Portege M200 Maintenance Manual 960 457 ...