JK-UC1 Operation 

The JK-UC1 has the ability to control Toshiba-TAIS  cameras , as well as any Toshiba ‘P’ or Pelco 
‘P’ compatible dome camera. 
For doing so, the controller has 23 keys, a joystick and two displays, as shown in fig. 7. Refer to this 
figure or straight to the keyboard from now and on to relate to the functions of the unit. It is strongly 
recommended to practice every function several times to get used to the operation of the system. 
To simplify operations, the JK-UC1 has shortcuts to access each of those modes, even though it 
keeps the Pelco procedure to access them. From  this point and on, this manual will describe the 
shortcuts to access the different commands. At the end of this section there is a cross reference 
table to the alternative methods to access them. A regular Pelco user can feel free to use the way 
he or she is used to operate the controller. 

 

Содержание JK-UC1

Страница 1: ...Installation and Operation Manual JK UC1 Universal Controller ...

Страница 2: ...Compensation 11 AF Trigger 11 WB Trigger 12 IR Filter 13 Version 13 Scanning Functions 13 Scan Limits 14 Patterns 14 Start Pattern 14 End Pattern 14 Set Preset 15 Clear Preset 15 Go to Preset 15 Special Presets 15 Remote Reset 16 Soft Reset for the JK UC1 16 SPECIFICATIONS 17 GENERAL 17 Ambient Operating 17 ELECTRICAL 17 Keyboard Communication 17 Others 17 Ilustrations Figure 1 4 Figure 2 5 Figure...

Страница 3: ...his manual prior to installation and operation of the JK UC1 or any other accessory of the system REGULATORY NOTICES The JK UC1 complies with the limits of a Class A Digital Device as described in part 15 of the FCC rules This implies that the JK UC1 does not generate harmful interference when operated in a commercial environment This equipment generates uses and can radiate radio frequency energy...

Страница 4: ...Manual this one 7 A plastic bag Figure 1 The lack of any of the above mentioned items MUST be referred to the dealer as soon as possible DESCRIPTION The JK UC1 Universal Controller was designed to control up to 255 Toshiba P or Pelco P compatible cameras directly wired to it A special Switcher is needed to route video to the monitor The JK UC1 has a 3 axis joystick that lets you control the zoom p...

Страница 5: ...n Configuration fig 1 a Star Configuration fig 2 or any combination of the above It is important to remember NOT to connect more than 32 receivers in a Star Configuration parallel to one another Daisy Chain Figure 2 Bus Configuration Figure 3 The installation requires a video switcher to route the cameras output and display it in a monitor ...

Страница 6: ...ker 2 Wire the transmission wires into pins 3 TX and 6 TX See fig 3 Figure 4 3 Place the JK UC1 unit in its assigned location It is recommended for them not to be farther than 2 meters to be plugged with the cable included in the kit but this is not needed In other cases the cable is a standard one to one UTP cable ended on both sides in RJ 45 connectors It is important for the data and power cabl...

Страница 7: ...t be done whatsoever However if the unit is going to act as a slave unit in the RS 485 line every jumper on the A group must be taken off Refer to fig 5 In case the unit is going to use a RS 232 communication line the jumpers on the B group must be changed to the left side as shown in fig 6 This is the case when trying to communicate the unit and a PC In case the communication would be RS 485 no c...

Страница 8: ...8 Figure 7 ...

Страница 9: ...s strongly recommended to practice every function several times to get used to the operation of the system To simplify operations the JK UC1 has shortcuts to access each of those modes even though it keeps the Pelco procedure to access them From this point and on this manual will describe the shortcuts to access the different commands At the end of this section there is a cross reference table to ...

Страница 10: ...10 ...

Страница 11: ...tart the input again 3 Once the number of the camera appears on the left display press CAMERA key The controller will display Cam on the right side for a moment and then will come back to the normal display situation Example If the unit has the camera 23 selected and you want to select camera number 125 1 Input 1 then 2 then 5 in the number keypad The display will show 125 023 2 Press CAMERA key T...

Страница 12: ... this procedure 1 Press the Shift key so that the light in it turns on 2 Press the IRIS IN key The JK UC1 will display W B on the right display for a moment After that the result of the sequence will be seen in the screen and the displays will go back to show the selected camera number ...

Страница 13: ... the sequence will be seen in the monitor and the displays will go back to show the selected camera number Scanning Functions There are five kinds of scanning functions implemented in the JK UC1 according to the amount of functions that could be included in your dome Auto Scan Auto Patrol Random Scan Frame Scan Pattern The definition of each one is in each dome s manual To stop any of these scanni...

Страница 14: ...sition at which you want to set the STOP 2 Define if this position is going to be the Right Scan Limit or the Left one 3 To set the Right Manual Scan Limit c Type down 91 using the number keypad d Press Preset The JK UC1 will display RMLm on the right display for a moment After that the Stop is settled and the displays goes back to show the selected camera number 4 To set the Left Manual Scan Limi...

Страница 15: ...oment After that the preset is erased and the displays will go back to show the selected camera number Go to Preset To go to a Preset follow this sequence 1 Type down the number of the preset you want to go to using the number keypad 2 Press the Preset key The JK UC1 will display PrSt on the right display for a moment After that the dome will go to the selected preset and the displays will go back...

Страница 16: ...K UC1 can send a RESET Command to the dome camera To do so go to Preset number 257 Soft Reset for the JK UC1 In case of need the JK UC1 can be reset by going to the Preset number 258 This procedure runs the initial sequence clears all buffers and starts anew ...

Страница 17: ...n LED Ambient Operating Temperature 20º to 120ºF 7º to 49ºC Humidity 10 90 non condensing ELECTRICAL Input Voltage 9 VAC or 9 VDC Power Consumption 2 watt Connector Type RJ 45 8 pin modular female Keyboard Communication Interface RS 485 Protocol Toshiba P Pelco P Baud Rate 4800 bps Communication Parameters Parameters 8 data bits odd parity 1 stop bit Others Weight 5 9 Pounds 2 2 Kg Length 10 6 in ...