Light-Load High-Speed Operation Load Wait Time
Program
⇒
Special Control Parameters
⇒
Crane/Hoist Settings
⇒
Express Speed Settings
⇒
Light-Load High-Speed Operation Load
Wait-Time
After the time setting of
F333
times out, this parameter determines the length of
time that the Light-Load High-Speed criteria must be met until the Light-
Load High-Speed function engages.
Direct Access Number — F332
Parameter Type — Numerical
Factory Default — 1.0
Changeable During Run — Yes
Minimum — 0.0
Maximum — 10.0
Units — Seconds
Light-Load High-Speed Operation Load Detection Time
Program
⇒
Special Control Parameters
⇒
Crane/Hoist Settings
⇒
Express Speed Settings
⇒
Light-Load High-Speed Operation Load
Detection Time
This parameter determines the length of time that the load requirement must
meet the Light-Load High-Speed criteria before the Light-Load High-Speed
Enable (
F330
) is recognized.
Once recognized, the timer setting of
F332
must expire to engage the Light-
Load High-Speed function.
Direct Access Number — F333
Parameter Type — Yes
Factory Default — 1.0
Changeable During Run — Numerical
Minimum — 0.0
Maximum — 10.0
Units — Seconds
Light-Load High-Speed Operation Heavy-Load Detection
Time
Program
⇒
Special Control Parameters
⇒
Crane/Hoist Settings
⇒
Express Speed Settings
⇒
Light-Load High-Speed Operation Heavy-
Load Detection Time
While operating in the Light-Load High-Speed mode, this parameter
determines the length of time that a load exceeding the Light-Load High-
Speed operation criteria may exist before the Light-Load High-Speed mode is
terminated and normal operation resumes.
Direct Access Number — F334
Parameter Type — Numerical
Factory Default — 5.0
Changeable During Run — Yes
Minimum — 0.0
Maximum — 10.0
Units — Seconds
Switching Load Torque During Forward-Run
Program
⇒
Special Control Parameters
⇒
Crane/Hoist Settings
⇒
Express Speed Settings
⇒
Switching Load Torque During Forward
Run
While running forward, this parameter establishes the threshold torque level
that is used to determine if the Light-Load High-Speed (
F331
) operation may
engage or remain engaged if active.
If the Light-Load High-Speed operation is terminated normal operation
resumes.
Direct Access Number — F335
Parameter Type — Numerical
Factory Default — 50
Changeable During Run — No
Minimum — 0
Maximum — 250
Units — %
Heavy-Load Torque During Forward Acceleration
Program
⇒
Special Control Parameters
⇒
Crane/Hoist Settings
⇒
Express Speed Settings
⇒
Heavy-Load Torque During Forward
Acceleration
During forward acceleration, this parameter establishes the threshold torque
level that is used to determine if the Light-Load High-Speed (
F331
) operation
may engage or remain engaged if active.
If the Light-Load High-Speed operation is terminated normal operation
resumes.
Direct Access Number — F336
Parameter Type — Numerical
Factory Default — 150
Changeable During Run — Yes
Minimum — 0
Maximum — 250
Units — %