9
operation panel support
bracket screws
operation panel
support bracket
Figure 3:
EIII with front cover removed
10. Turn all power sources to the inverter unit ON, and verify that the inverter functions
properly. If the inverter unit does not appear to power up, or does not function
properly, immediately turn power OFF.
Repeat steps 1
∼
3 to remove all power
from the inverter.
Then, verify all connections. Contact Toshiba International
Corporation for assistance if the problem persists.