
e-STUDIO3511/4511 TROUBLESHOOTING
5 - 74
November 2003 © TOSHIBA TEC
5.1.18 Copy process related service call
[C360] Charger cleaner motor abnormality
(1) Check if the main charger is installed normally.
(2) Check if the charger wire is broken.
(3) Check if any of the connector pins of the charger cleaner front/rear position detection switch is
disconnected.
(4) Check if the cleaning pads are damaged or removed.
(5) Check if any of the connector pins of the charger cleaner motor is disconnected.
(6) Replace the charger cleaner motor.
(7) Replace the LGC board.
[C970] High-voltage transformer abnormality
(1) Is the main charger installed securely?
(2) Check if the spring of high-voltage supply contact point is deformed.
(3) Check if the charger wire is broken or the main charger grid is deformed.
(4) Check if any foreign matter is on the charger wire or main charger grid.
[CEA0] Revolver home position detection abnormality
Is the revolver home position sensor working properly? (Perform the input check: 03-[FAX]ON/[2]/[C])
NO
1. Check if the connector or joint connector of the revolver home position sensor is
disconnected.
2. Check if the connector CN361 on the LGC board is disconnected.
3. Check if the connector pins are disconnected or the wires of harnesses are
open circuited.
4. Check if the conductor pattern on the LGC board is short circuited or open
circuited.
5. Replace the revolver home position sensor.
6. Replace the LGC board.
YES
1. Check if the conductor pattern on the LGC board is short circuited or open circuited.
2. Replace the LGC board.
Содержание e-STUDIO3511
Страница 2: ... 2003 TOSHIBA TEC CORPORATION All rights reserved ...
Страница 10: ...e STUDIO3511 4511 CONTENTS vi November 2003 TOSHIBA TEC ...
Страница 12: ......
Страница 20: ...e STUDIO3511 4511 SPECIFICATIONS 1 8 November 2003 TOSHIBA TEC ...
Страница 190: ...e STUDIO3511 4511 ERROR CODE AND SELF DIAGNOSTIC MODE 2 170 November 2003 TOSHIBA TEC ...
Страница 423: ...November 2003 TOSHIBA TEC 5 109 e STUDIO3511 4511 TROUBLESHOOTING 4 Background fogging Fig 5 205 ...
Страница 425: ...November 2003 TOSHIBA TEC 5 111 e STUDIO3511 4511 TROUBLESHOOTING A B 5 Moire lack of sharpness Fig 5 206 ...
Страница 430: ...e STUDIO3511 4511 TROUBLESHOOTING 5 116 November 2003 TOSHIBA TEC 9 Blank print Feeding direction Fig 5 210 ...
Страница 456: ...e STUDIO3511 4511 TROUBLESHOOTING 5 142 November 2003 TOSHIBA TEC ...
Страница 518: ...e STUDIO3511 4511 FIRMWARE UPDATING 6 62 November 2003 TOSHIBA TEC ...
Страница 546: ...e STUDIO3511 4511 REMOTE SERVICE 8 24 November 2003 TOSHIBA TEC 7 ...
Страница 548: ...e STUDIO3511 4511 WIRE HARNESS CONNECTION DIAGRAMS 9 2 November 2003 TOSHIBA TEC ...
Страница 551: ......
Страница 552: ...2 17 2 HIGASHIGOTANDA SHINAGAWA KU TOKYO 141 8664 JAPAN ...