Chapter 5 Setting with the Engineering Tool
6F8C1583
52
■
Transmit Processing Operation
----Send error is occurred.
Trans data
TX_RDY
(2)
(5)
TX_CMP
Sending Error
TX_ERR
(3)
CF622 Control
User's application
MWRITE instruction
(1)
MREAD instruction
(4)
TX_ST
Send data
Error Info.
Figure 5-25 Send processing operation (error)
(2) If sending error is occurred, TX_ERR is set to 1 and TX_RDY is set to 1 after (1).
(3) Reading error information using MREAD instruction.
(4) Set TX_ST to 0 from user’s application.
(5) TX_ERR is reset to 0, TX_RDY is reset to 1 and a next sending is available.