background image

Toshiba

– 2 –

Fresh-air inlet box

Installation Manual

EN

1

APPLICABLE MODELS

2

ACCESSORIES

(The following parts are included.)

3

INSTALLING THE FRESH-AIR INLET BOX

CAUTION

The Fresh-air inlet box should be installed after installing the indoor unit. Further attention is required since the Fresh-
air inlet box is attached to the Fresh-air chamber. Applying the shock to the side of the Fresh-air chamber may damage 
the product.
Wear safety globes to carry out these works. Do not attempt with bare hands.

1

Install the indoor unit on ceiling. Connect the system interconnection wire and remote control 
wire.

• Refer to the installation manual of the indoor unit for the details.
• Connect the (9) wire, if a duct fan (locally procured) is installed.

2

Attach the Fresh-air chamber to the indoor unit.

For the details, refer to the Fresh-air chamber 
installation manual.

3

Remove the shield plate for box from the Fresh-
air chamber. (Fig. 1)

4

Remove the shield plate assembly from the 
Fresh-air chamber. (This part will be attached 
back later.) (Fig. 1)

Indoor unit

RAV-SP 0UT-UL

Fresh-air chamber

TCB-GFC1602UUL

No.

Name

Shape

Q’ty No.

Name

Shape

Q’ty No.

Name

Shape

Q’ty

Remark

(1)

Outside air 

introduction 

port

1

(4)

Mounting 

screws 
0.16” x 0.4” 

(4 x 10 mm)

16

(7) Wind shield

1

(2)

Outside air 

introduction 

port fixing 

metal part

1

(5)

Heat 

insulating 

material A

2

(8) Installation 

manual

1

This 

manual

(3)

Duct flange 

Ø3.9” (100 

mm)

1

(6)

Heat 

insulating 

material B

2

(9) Wire

1

**

(5) Heat insulating 

material A

Shield plate for box

(Remove)

(Fig. 1)

(6) Heat insulating material B

Shield plate assembly

2-EN

+00EH99678601_01EN_FreshAirInletBox-IM.book  Page 2  Tuesday, December 8, 2009  2:03 PM

Содержание Carrier TCB-GB1602UUL

Страница 1: ...PLIT TYPE Fresh Air Inlet Box for 4 way Air Discharge Cassette Type Model name Fresh air inlet box TCB GB1602UUL Installation Manual Installation Manual Fresh air inlet box 1 English Manuel d installation Boîte d entrée d air frais 7 Français ...

Страница 2: ... require hospitalization or long term treatment as an outpatient 2 Physical damage indicates the damage relating to the property material CAUTION ON INSTALLATION WARNING Use TOSHIBA Carrier products for the parts sold separately Use the products specified by TOSHIBA Carrier for the parts sold separately such as the fresh air chamber ceiling panel etc The use of the products other than specified ma...

Страница 3: ...the 9 wire if a duct fan locally procured is installed 2 Attach the Fresh air chamber to the indoor unit For the details refer to the Fresh air chamber installation manual 3 Remove the shield plate for box from the Fresh air chamber Fig 1 4 Remove the shield plate assembly from the Fresh air chamber This part will be attached back later Fig 1 Indoor unit RAV SP 0UT UL Fresh air chamber TCB GFC1602...

Страница 4: ...0Attach back the shield plate assembly removed in 3 4 as it was installed 11Fix the wind shield 7 to the position where the suction grille is removed as shown in the Fig 3 with 2 mounting screws 4 If the wind shield is not fixed it is impossible to control the room temperature This may cause improper operation CAUTION Be sure to provide the opening for inspection on the Fresh air inlet box side Th...

Страница 5: ...ible duct to the external side of the flange circle and fix it by using a band at 1 to 1 2 25 to 30 mm position from the edge of the flexible duct 2 Sealing the connection port Wrap the tightening band with the heat insulating materials of 0 79 20 mm thickness or more Apply the adhesive tape around the heat insulating materials of the connection port to prevent the heat insulating materials from p...

Страница 6: ...hick line shows the connection circuit After installing the duct perform the test run to confirm whether the duct fan and the ventilation of the indoor unit work starting or stopping at the same timing For the test run following to the instructions described on the indoor unit installation manual Indoor unit Fresh air chamber Sound insulation chamber Duct fan Outside air filter Processed outside a...

Страница 7: ... 6 Fresh air inlet box Installation Manual EN MEMO ...

Страница 8: ...EH99678601 1 ...

Отзывы: